Effects of Mesenteric Ischemia and Reperfusion on Small Bowel Electrical Activity
Overview
Affiliations
Unlabelled: Previous studies involving basic electrical rhythm (BER) have not been carried out far enough to fully characterize the relationship between mesenteric ischemia and BER. The phenomenon of reperfusion injury has also not been correlated with BER activity. The goal of this study was to characterize changes in BER during mesenteric ischemia and reperfusion and to correlate them with changes in pathology.
Methods: Serosal electrodes were used to record the electrical activity of rabbit jejunum (n = 20) at baseline, during ischemia (90-210 min), and during reperfusion (120-240 min). BER frequency and amplitude were monitored, and biopsies were taken at the end of ischemia and reperfusion. A pathologist blinded to the specimen identity graded the histology on a scale of 0 (no changes) to 6 (transmural necrosis). Paired t test, the Kruskal-Wallis test of non-parametric ranks, and Fisher's r to z test were used for statistical significance where appropriate.
Results: BER frequency and amplitude fell significantly after 15 min of ischemia and became undetectable by 90 min of ischemia in all animals. The likelihood that BER would return during reperfusion was highly correlated with length of ischemia (r = 0.99). Longer periods of reperfusion were associated with increasing pathologic grade.
Conclusions: BER frequency and amplitude are very sensitive to ischemia and their changes occur well before histopathologic changes. The variation in electrical activity of the small bowel during ischemia and reperfusion is a dynamic process that reflects the metabolic state of the smooth muscle. If electrical activity of the bowel is to be used for assessment of viability, continuous recordings more accurately reflect the metabolic state of the smooth muscle.
Kuruppu S, Cheng L, Angeli-Gordon T, Avci R, Paskaranandavadivel N Ann Biomed Eng. 2023; 52(3):588-599.
PMID: 37962674 DOI: 10.1007/s10439-023-03404-w.
Bioluminescence Imaging for Targeting Acute Hypoxic/Ischemic Small Intestine with Engineered .
Moon C, Zheng J, Min J, Jeong Y, Heo S, Shin S Mol Ther Methods Clin Dev. 2020; 18:484-492.
PMID: 32728597 PMC: 7381499. DOI: 10.1016/j.omtm.2020.06.021.
Magnetoenterography for the Detection of Partial Mesenteric Ischemia.
Somarajan S, Muszynski N, Olson J, Bradshaw L, Richards W J Surg Res. 2019; 239:31-37.
PMID: 30782544 PMC: 6506857. DOI: 10.1016/j.jss.2019.01.034.
Ischemia/reperfusion injury in porcine intestine - Viability assessment.
Strand-Amundsen R, Reims H, Reinholt F, Ruud T, Yang R, Hogetveit J World J Gastroenterol. 2018; 24(18):2009-2023.
PMID: 29760544 PMC: 5949714. DOI: 10.3748/wjg.v24.i18.2009.
Somarajan S, Muszynski N, Cheng L, Bradshaw L, Naslund T, Richards W Am J Physiol Gastrointest Liver Physiol. 2015; 309(1):G52-8.
PMID: 25930082 PMC: 4491509. DOI: 10.1152/ajpgi.00466.2014.