» Articles » PMID: 9526896

Telemetry Pill Measurement of Core Temperature in Humans During Active Heating and Cooling

Overview
Specialty Orthopedics
Date 1998 Apr 4
PMID 9526896
Citations 57
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: This study compared the agreement between core temperature measurements obtained using an ingestible temperature pill telemetry system (Tpill) with those obtained from rectal (Tre) and esophageal (Tes) thermocouples under conditions of increasing and decreasing body temperature.

Methods: Four men and five women (age 25+/-2 yr, BSA 1.81+/-0.05 m2, VO2 peak 3.1+/-0.4 L x min[-1]) participated in four 3-h trials: cold (18 degrees C) water rest (CWR), cold water exercise (CWE), warm (36 degrees C) water rest (WWR), and warm water exercise (WWE). Subjects were immersed to the neck for each trial. During resting trials, subjects sat quietly. During exercise trials, subjects completed three bouts of 15 min of rest, followed by 45 min of exercise on a cycle ergometer at 50% of peak oxygen uptake. The temperature pill was taken 10-12 h before testing, after which the subjects fasted.

Results: The trials created conditions of constantly decreasing (CWR) or increasing (WWR) core temperature, as well as periods of oscillating core temperature (CWE and WWE). Root mean squared deviation (RMSD) was calculated for each pair of measurements (Tpill vs Tre, Tpill vs Tes, Tre vs Tes) for each trial. An RMSD of "0" indicates perfect agreement; as RMSD increases, agreement worsens. On CWR, the RMSD for Tpill-Tes (0.23+/-0.04) was lower (P < 0.05) than for Tpill-Tre (0.43+/-0.10) or Tre-Tes (0.46+/-0.09). There were no significant differences in RMSD between measurement pairs on any other trial (average RMSD = 0.26 degrees C). Telemetry pill temperature and response time tended to be intermediate between Tre and Tes.

Conclusion: These results suggest the telemetry pill system provides a valid measurement of core temperature during conditions of decreasing as well as increasing body temperature and during steady state.

Citing Articles

Thermal mapping: Assessing the optimal sites for temperature measurement in the human body and emerging technologies.

Yu L, Delgado J, De Mezerville R Physiol Rep. 2024; 12(14):e16155.

PMID: 39039617 PMC: 11262999. DOI: 10.14814/phy2.16155.


Heat stress in horses: a literature review.

Kang H, Zsoldos R, Sole-Guitart A, Narayan E, Cawdell-Smith A, Gaughan J Int J Biometeorol. 2023; 67(6):957-973.

PMID: 37060454 PMC: 10267279. DOI: 10.1007/s00484-023-02467-7.


Ethical dilemmas and validity issues related to the use of new cooling technologies and early recognition of exertional heat illness in sport.

Muniz-Pardos B, Angeloudis K, Guppy F, Tanisawa K, Hosokawa Y, Ash G BMJ Open Sport Exerc Med. 2021; 7(2):e001041.

PMID: 33927884 PMC: 8048013. DOI: 10.1136/bmjsem-2021-001041.


Time following ingestion does not influence the validity of telemetry pill measurements of core temperature during exercise-heat stress: The journal toolbox.

Notley S, Meade R, Kenny G Temperature (Austin). 2021; 8(1):12-20.

PMID: 33553501 PMC: 7849685. DOI: 10.1080/23328940.2020.1801119.


Separate and combined effects of cold dialysis and intradialytic exercise on the thermoregulatory responses of hemodialysis patients: a randomized-cross-over study.

Krase A, Flouris A, Karatzaferi C, Giannaki C, Stefanidis I, Sakkas G BMC Nephrol. 2020; 21(1):524.

PMID: 33267815 PMC: 7709248. DOI: 10.1186/s12882-020-02167-z.