» Articles » PMID: 9485587

Measuring Regularity by Means of a Corrected Conditional Entropy in Sympathetic Outflow

Overview
Journal Biol Cybern
Specialties Neurology
Physiology
Date 1998 Mar 5
PMID 9485587
Citations 59
Authors
Affiliations
Soon will be listed here.
Abstract

A new method for measuring the regularity of a process over short data sequences is reported. This method is based on the definition of a new function (the corrected conditional entropy) and on the extraction of its minimum. This value is taken as an index in the information domain quantifying the regularity of the process. The corrected conditional entropy is designed to decrease in relation to the regularity of the process (like other estimates of the entropy rate), but it is able to increase when no robust statistic can be performed as a result of a limited amount of available samples. As a consequence of the minimisation procedure, the proposed index is obtained without an a-priori definition of the pattern length (i.e. of the embedding dimension of the reconstructed phase space). The method is validated on simulations and applied to beat-to-beat sequences of the sympathetic discharge obtained from decerebrate artificially ventilated cats. At control, regular, both quasiperiodic and periodic (locked to ventilation) dynamics are observed. During the sympathetic activation induced by inferior vena cava occlusion, the presence of phase-locked patterns and the increase in regularity of the sympathetic discharge evidence an augmented coupling between the sympathetic discharge and ventilation. The reduction of complexity of the neural control obtained by spinalization decreases the regularity in the sympathetic outflow, thus pointing to a weaker coupling between the sympathetic discharge and ventilation.

Citing Articles

A method to assess linear self-predictability of physiologic processes in the frequency domain: application to beat-to-beat variability of arterial compliance.

Sparacino L, Antonacci Y, Bara C, Svec D, Javorka M, Faes L Front Netw Physiol. 2024; 4:1346424.

PMID: 38638612 PMC: 11024367. DOI: 10.3389/fnetp.2024.1346424.


Gradients of O-information highlight synergy and redundancy in physiological applications.

Scagliarini T, Sparacino L, Faes L, Marinazzo D, Stramaglia S Front Netw Physiol. 2024; 3:1335808.

PMID: 38264338 PMC: 10803408. DOI: 10.3389/fnetp.2023.1335808.


: a free software for analyzing cardiac, vascular and respiratory interactions.

Pichot V, Corbier C, Chouchou F, Barthelemy J, Roche F Front Physiol. 2024; 14:1224440.

PMID: 38250656 PMC: 10797906. DOI: 10.3389/fphys.2023.1224440.


What can entropy metrics tell us about the characteristics of ocular fixation trajectories?.

Melnyk K, Friedman L, Komogortsev O PLoS One. 2024; 19(1):e0291823.

PMID: 38166054 PMC: 10760742. DOI: 10.1371/journal.pone.0291823.


Effects of High Intensity Interval Training versus Sprint Interval Training on Cardiac Autonomic Modulation in Healthy Women.

Oliveira J, Gentil P, Naves J, Souza Filho L, Silva L, Zamuner A Int J Environ Res Public Health. 2022; 19(19).

PMID: 36232163 PMC: 9566246. DOI: 10.3390/ijerph191912863.