» Articles » PMID: 9457792

The Area of Complete Scotopic Spatial Summation Enlarges with Age

Overview
Specialty Ophthalmology
Date 1998 Feb 11
PMID 9457792
Citations 17
Authors
Affiliations
Soon will be listed here.
Abstract

The maximal area of complete scotopic spatial summation (Ricco's area) was determined for 50 subjects ranging in age from 19 to 87 yr. Increment thresholds were measured for 10-ms, 520-nm circular test lights of varying diameters that were superimposed and concentric with a 10 degrees, 640-nm circular background. The test lights were imaged in Maxwellian view along the horizontal meridian, 6 degrees nasal from a foveal fixation point. The results demonstrate a statistically significant enlargement of Ricco's area with age. The average angular subtenses of Ricco's areas for the ten youngest (mean = 26 yr) and ten oldest (mean = 75 yr) observers were approximately 48 and 69 arc min, respectively. Model simulations based on a series of optical transfer functions of the eye and varying degrees of intraocular light scatter for younger and older observers show that preneural factors cannot account for these results. Therefore changes in neural mechanisms must be invoked to explain the enlargement in the size of Ricco's area under scotopic conditions.

Citing Articles

Impact of Glaucomatous Ganglion Cell Damage on Central Visual Function.

Kwon M Annu Rev Vis Sci. 2024; 10(1):425-453.

PMID: 39292555 PMC: 11529636. DOI: 10.1146/annurev-vision-110223-123044.


Retinal Ganglion Cell Content Underlying Standard Automated Perimetry Size I to V Visual Sensitivities in the Non-Human Primate Experimental Glaucoma Model.

Venkata Srinivasan V, Carter-Dawson L, Patel N Invest Ophthalmol Vis Sci. 2024; 65(8):22.

PMID: 38995114 PMC: 11246096. DOI: 10.1167/iovs.65.8.22.


Establishing Fully-Automated Fundus-Controlled Dark Adaptometry: A Validation and Retest-Reliability Study.

Oertli J, Pfau K, Scholl H, Jeffrey B, Pfau M Transl Vis Sci Technol. 2023; 12(12):18.

PMID: 38112496 PMC: 10732091. DOI: 10.1167/tvst.12.12.18.


Scotopic Contour Deformation Detection Reveals Early Rod Dysfunction in Age-Related Macular Degeneration With and Without Reticular Pseudodrusen.

Jeffrey B, Flynn O, Huryn L, Pfau M, Cukras C Invest Ophthalmol Vis Sci. 2022; 63(6):23.

PMID: 35749129 PMC: 9234356. DOI: 10.1167/iovs.63.6.23.


The perception threshold of the panda illusion, a particular form of 2D pulse-width-modulated halftone, correlates with visual acuity.

Strasser T, Kurtenbach A, Langrova H, Kuehlewein L, Zrenner E Sci Rep. 2020; 10(1):13095.

PMID: 32753676 PMC: 7403154. DOI: 10.1038/s41598-020-69952-6.