Feasibility of Using Finger Arterial Pressure in Neonates

Overview
Date 1998 Feb 12
PMID 9377138
Citations 9
Authors
Affiliations
Soon will be listed here.
Abstract

The feasibility of using a Finapres device to reproduce the beat to beat signal of arterial blood pressure in eight neonates was assessed and compared with intra-arterial measurement of arterial blood pressure in the umbilical artery, using a catheter. The two methods gave similar results. Continuous recording of arterial blood pressure in neonates using Finapres is feasible and reliable.

Citing Articles

History of blood pressure measurement in newborns and infants.

Javorka K Physiol Res. 2023; 72(5):543-555.

PMID: 38015754 PMC: 10751046. DOI: 10.33549/physiolres.935173.


Clinical Study of Continuous Non-Invasive Blood Pressure Monitoring in Neonates.

Rao A, Eskandar-Afshari F, Weiner Y, Billman E, McMillin A, Sella N Sensors (Basel). 2023; 23(7).

PMID: 37050750 PMC: 10098632. DOI: 10.3390/s23073690.


Noninvasive assessment of autonomic function in human neonates born at the extremes of fetal growth spectrum.

Dissanayake H, McMullan R, Gordon A, Caterson I, Celermajer D, Phang M Physiol Rep. 2018; 6(8):e13682.

PMID: 29687617 PMC: 5913591. DOI: 10.14814/phy2.13682.


Baroreflex dysfunction in sick newborns makes heart rate an unreliable surrogate for blood pressure changes.

Govindan R, Al-Shargabi T, Massaro A, Metzler M, Andescavage N, Joshi R Pediatr Res. 2016; 79(6):929-33.

PMID: 26859365 PMC: 4899139. DOI: 10.1038/pr.2016.17.


Cerebrovascular control is altered in healthy term infants when they sleep prone.

Wong F, Yiallourou S, Odoi A, Browne P, Walker A, Horne R Sleep. 2013; 36(12):1911-8.

PMID: 24293766 PMC: 3825441. DOI: 10.5665/sleep.3228.


References
1.
ORourke M, BLAZEK J, Morreels Jr C, KROVETZ L . Pressure wave transmission along the human aorta. Changes with age and in arterial degenerative disease. Circ Res. 1968; 23(4):567-79. DOI: 10.1161/01.res.23.4.567. View

2.
Bland J, Altman D . Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986; 1(8476):307-10. View

3.
Tanaka H, Thulesius O, Yamaguchi H, Mino M, Konishi K . Continuous non-invasive finger blood pressure monitoring in children. Acta Paediatr. 1994; 83(6):646-52. DOI: 10.1111/j.1651-2227.1994.tb13100.x. View

4.
Tanaka H, Thulesius O . Effect of temperature on finger artery pressure evaluated by volume clamp technique. Clin Physiol. 1993; 13(5):535-45. DOI: 10.1111/j.1475-097x.1993.tb00469.x. View

5.
Parati G, Casadei R, Groppelli A, Di Rienzo M, Mancia G . Comparison of finger and intra-arterial blood pressure monitoring at rest and during laboratory testing. Hypertension. 1989; 13(6 Pt 1):647-55. DOI: 10.1161/01.hyp.13.6.647. View