» Articles » PMID: 9220735

Cyclic Fatigue Testing of Nickel-titanium Endodontic Instruments

Overview
Journal J Endod
Publisher Elsevier
Specialty Dentistry
Date 1997 Feb 1
PMID 9220735
Citations 172
Authors
Affiliations
Soon will be listed here.
Abstract

Cyclic fatigue of nickel-titanium, engine-driven instruments was studied by determining the effect of canal curvature and operating speed on the breakage of Lightspeed instruments. A new method of canal curvature evaluation that addressed both angle and abruptness of curvature was introduced. Canal curvature was simulated by constructing six curved stainless-steel guide tubes with angles of curvature of 30, 45, or 60 degrees, and radii of curvature of 2 or 5 mm. Size #30 and #40 Light-speed instruments were placed through the guide tubes and the heads secured in the collet of a Mangtrol Dynamometer. A simulated operating load of 10 g-cm was applied. Instruments were able to rotate freely in the test apparatus at speeds of 750, 1300, or 2000 rpm until separation occurred. Cycles to failure were determined. Cycles to failure were not affected by rpm. Instruments did not separate at the head, but rather at the point of maximum flexure of the shaft, corresponding to the midpoint of curvature within the guide tube. The instruments with larger diameter shafts, #40, failed after significantly fewer cycles than did #30 instruments under identical test conditions. Multivariable analysis of variance indicated that cycles to failure significantly decreased as the radius of curvature decreased from 5 mm to 2 mm and as the angle of curvature increased greater than 30 degrees (p < 0.05, power = 0.9). Scanning electron microscopic evaluation revealed ductile fracture as the fatigue failure mode. These results indicate that, for nickel-titanium, engine-driven rotary instruments, the radius of curvature, angle of curvature, and instrument size are more important than operating speed for predicting separation. This study supports engineering concepts of cyclic fatigue failure and suggests that standardized fatigue tests of nickel-titanium rotary instruments should include dynamic operation in a flexed state. The results also suggest that the effect of the radius of curvature as an independent variable should be considered when evaluating studies of root canal instrumentation.

Citing Articles

Temperature-Dependent Effects on Cyclic Fatigue Resistance in Three Reciprocating Endodontic Systems: An In Vitro Study.

Salamanca Ramos M, Aranguren J, Malvicini G, De Gregorio C, Bonilla C, Perez A Materials (Basel). 2025; 18(5).

PMID: 40077177 PMC: 11901110. DOI: 10.3390/ma18050952.


Thermal behavior and cyclic fatigue resistance of three contemporary NiTi heat-treated single-file systems: metallurgical study.

Alsofi L, Al-Marshadi M, AbuHaimed T, Al-Habib M, Saif R, Bukhari S BMC Oral Health. 2025; 25(1):338.

PMID: 40038622 PMC: 11881276. DOI: 10.1186/s12903-025-05708-w.


Evaluation of cyclic fatigue in three pediatric endodontic rotary file systems in root canals of primary molars: A finite element analysis (FEA).

S S M, Vignesh K, Vivek K, Swaminathan K, Haridoss S J Oral Biol Craniofac Res. 2025; 15(2):310-318.

PMID: 40027856 PMC: 11870175. DOI: 10.1016/j.jobcr.2025.01.023.


Comparison of the effect of different irrigation activation systems on the amount of apical extrusion of irrigation solution in teeth with severely curved canals.

Karadagli M, Ugur Aydin Z Lasers Med Sci. 2025; 40(1):27.

PMID: 39841307 DOI: 10.1007/s10103-024-04243-4.


The Biomechanics of Nickel Titanium Instrument Fracture in Root Canal Therapy: A Narrative Review.

Ohri K, Chien P, Peters O Materials (Basel). 2025; 17(24.

PMID: 39769746 PMC: 11678187. DOI: 10.3390/ma17246147.