» Articles » PMID: 9189150

Quantification of Left Ventricular Function with Thallium-201 and Technetium-99m-sestamibi Myocardial Gated SPECT

Overview
Journal J Nucl Med
Specialty Nuclear Medicine
Date 1997 Jun 1
PMID 9189150
Citations 24
Authors
Affiliations
Soon will be listed here.
Abstract

Unlabelled: Myocardial gated SPECT with 99mTc-sestamibi has been used to quantify left ventricular function. The purpose of this study was to determine if myocardial gated SPECT with 201Tl was possible and reliable to quantify left ventricular function.

Methods: One hundred and four patients referred for a myocardial perfusion study were included. Myocardial gated SPECT acquisition was performed 15 min after the intravenous injection of 111 MBq (3mCi) 201Tl and at 1 hr postinjection of 925 MBq (25 mCi) 99mTc-sestamibi. A commercially available automated myocardial gated SPECT processing software was used. Parameters evaluated were left ventricular ejection fractions (LVEF), end-diastolic volumes (EDV), end-systolic volumes (ESV) and stroke volumes (SV).

Results: The correlation between gated SPECT with 201Tl and gated SPECT with 99mTc-sestamibi was: r = 0.93 for LVEF, 0.92 for EDV, 0.96 for ESV and 0.68 for SV.

Conclusion: Myocardial gated SPECT quantification of left ventricular function with 201Tl was possible and as reliable as gated SPECT with 99mTc-sestamibi. There was excellent correlation between gated SPECT with 201Tl and gated SPECT with 99mTc-sestamibi. In addition to assessment of myocardial perfusion, myocardial function and viability can be quantified in a single gated 201Tl study.

Citing Articles

Assessment of Left Ventricular Ejection Fraction by Thallium-201 Myocardial SPECT-CT in Patients with Angina Pectoris: Comparison with 2D Echocardiography.

Kim J, Park H, Kim S, Chang H, Choi H, Kim Y Nucl Med Mol Imaging. 2019; 53(2):136-143.

PMID: 31057685 PMC: 6473012. DOI: 10.1007/s13139-019-00575-0.


Thallium-201 gated single-photon emission tomography for assessing left ventricular volumes and function in patients with aortic valve stenosis: Comparison with echocardiography as the reference standard.

Kurisu S, Iwasaki T, Ikenaga H, Watanabe N, Higaki T, Shimonaga T Int J Cardiol Heart Vasc. 2017; 5:74-78.

PMID: 28785618 PMC: 5497158. DOI: 10.1016/j.ijcha.2014.09.001.


Do reconstruction filters really effect the volume and ejection fraction calculation with 99Tc-sestamibigated myocardial SPECT?.

Manish O, Kheruka S, Barai S, Gambhir S Indian J Nucl Med. 2011; 25(4):156-9.

PMID: 21713224 PMC: 3109822. DOI: 10.4103/0972-3919.78251.


Dynamic single photon emission computed tomography--basic principles and cardiac applications.

Gullberg G, Reutter B, Sitek A, Maltz J, Budinger T Phys Med Biol. 2010; 55(20):R111-91.

PMID: 20858925 PMC: 3306016. DOI: 10.1088/0031-9155/55/20/R01.


Left ventricular ejection fraction assessment by Tl-201 gated SPECT: a comparison with echocardiography.

Harpaz D, Asman A, Kuperstein R, Boaz M, Chouraqui P Clin Cardiol. 2010; 33(3):E56-62.

PMID: 20127905 PMC: 6653043. DOI: 10.1002/clc.20577.