» Articles » PMID: 9179480

Comparison of Anterior, Posterior and Total Fundoplication Using a Viscera Model

Overview
Journal Dis Esophagus
Specialty Gastroenterology
Date 1997 Apr 1
PMID 9179480
Citations 10
Authors
Affiliations
Soon will be listed here.
Abstract

Objective: To determine the contribution of mechanical factors to the function of different types of fundoplication.

Design And Setting: An experimental bench-top study using abattoir-sourced pig esophagus and stomach placed on a tray. Preliminary esophageal myotomy ensured free reflux of 'intragastric fluid'.

Interventions: Anterior, posterior, and total fundoplications were performed on each of ten sets of viscera.

Main Outcome Measures: Lower esophageal sphincter pressure was measured using a conventional esophageal manometry catheter. Intragastric pressure was measured with a single channel intragastric manometry catheter, whilst the stomach was inflated with coloured water. The maximum intragastric pressure or the pressure measured when the fundoplication yielded to gastric distension was recorded.

Results: All three types of fundoplication restored adequate competence to the gastroesophageal junction, although high-volume gastric infusions resulted in fundoplication yield in 4/10 anterior and 4/10 posterior fundoplications. Gastric distension resulted in fundal dilatation and consequent compression of the adjacent esophagus. Fundoplication generated a median rise of 11-13.5 mmHg in lower esophageal sphincter pressure, comparable to pressures reported in the postoperative clinical setting. Significantly greater intragastric volumes and pressures were tolerated following total fundoplication.

Conclusions: This study suggests that mechanical factors could be major contributors to the ability of a fundoplication to restore gastroesophageal competence. Anterior, posterior and total fundoplications are all effective procedures.

Citing Articles

The Angle of His as a Measurable Element of the Anti-reflux Mechanism.

Michael S, Marom G, Brodie R, Abu Salem S, Fishman Y, Shein G J Gastrointest Surg. 2023; 27(11):2279-2286.

PMID: 37620664 DOI: 10.1007/s11605-023-05808-4.


Esophagogastric junction distensibility after fundoplication assessed with a novel functional luminal imaging probe.

Kwiatek M, Kahrilas K, Soper N, Bulsiewicz W, McMahon B, Gregersen H J Gastrointest Surg. 2009; 14(2):268-76.

PMID: 19911238 PMC: 2877633. DOI: 10.1007/s11605-009-1086-1.


Endoscopic implantation of polymethylmethacrylate augments the gastroesophageal antireflux barrier: a short-term study in a porcine model.

Freitag C, Kruel C, Duarte M, Sanches P, Thome P, Fornari F Surg Endosc. 2008; 23(6):1272-8.

PMID: 18815837 DOI: 10.1007/s00464-008-0145-0.


Improved reflux monitoring in the acute gastroesophageal reflux porcine model using esophageal multichannel intraluminal impedance measurement.

Muller-Stich B, Mehrabi A, Kenngott H, Mood Z, Funouni H, Reiter M J Gastrointest Surg. 2008; 12(8):1351-8.

PMID: 18498016 DOI: 10.1007/s11605-008-0547-2.


Endoscopic antireflux surgery: are we there yet?.

Watson D World J Surg. 2008; 32(8):1578-80.

PMID: 18427888 DOI: 10.1007/s00268-008-9603-z.