Non-exercise VO2max Estimation for Physically Active College Students
Overview
Authors
Affiliations
This study sought to develop a maximal oxygen consumption (VO2max) regression model derived strictly from self-reported non-exercise (N-EX) predictor variables. The VO2max (mean +/- SD; 44.05 +/- 6.6 ml.kg-1.min-1) of 100 physically active college students (50 females, 50 males), aged 18 to 29 yr, was measured using a treadmill protocol and open circuit calorimetry. Questionnaire-based predictor variables used in the N-EX regression model included (a) the subject's perceived functional ability (PFA) to walk, jog, or run given distances, (b) habitual physical activity (PA-R) data, (c) body mass index (BMI), and (d) gender. BMI (kg.m-2) was computed from self-reported body weight in pounds and self-reported body height in feet and inches. The questionnaire-based N-EX regression model (R = 0.85, SEE = 3.44 ml.kg-1.min-1) developed in this study exceeded the accuracy of previously developed N-EX regression models and is comparable to many exercise-based regression models in the literature. Cross-validation using PRESS (predicted residual sum of squares) statistics demonstrated minimal shrinkage (R = 0.84, SEE = 3.60 ml.kg-1.min-1) of the present regression model. The PFA data were useful in explaining observed VO2max variance (squared partial r2 = 0.155, P < 0.0001) and enhanced the ability of the N-EX regression model to accurately predict criterion VO2max. These results suggest that a questionnaire-based N-EX regression model provides a valid and convenient method for predicting VO2max in physically active college students.
Efficacy of aerobic exercise for HIV-associated neurocognitive disorders receiving ART: An RCT.
Nweke M, Mshunqane N S Afr J Physiother. 2025; 80(1):2104.
PMID: 39822344 PMC: 11736550. DOI: 10.4102/sajp.v80i1.2104.
Cardiorespiratory Fitness and Its Place in Medicine.
Ross R, Myers J Rev Cardiovasc Med. 2024; 24(1):14.
PMID: 39076861 PMC: 11270451. DOI: 10.31083/j.rcm2401014.
Perry A, Farber-Eger E, Gonzales T, Tanaka T, Robbins J, Murthy V Nat Med. 2024; 30(6):1711-1721.
PMID: 38834850 PMC: 11186767. DOI: 10.1038/s41591-024-03039-x.
Accuracy of the SenseWear Armband during Short Bouts of Exercise.
Wedge R, McCammon M, Meardon S Sports (Basel). 2024; 12(4).
PMID: 38668561 PMC: 11054583. DOI: 10.3390/sports12040093.
Fujita M, Kamibayashi K, Horiuchi M, Ebine N, Fukuoka Y Sci Rep. 2023; 13(1):15534.
PMID: 37726511 PMC: 10509255. DOI: 10.1038/s41598-023-42811-w.