» Articles » PMID: 9109561

The Distribution of Strain in the Human Cornea

Overview
Journal J Biomech
Specialty Physiology
Date 1997 May 1
PMID 9109561
Citations 19
Authors
Affiliations
Soon will be listed here.
Abstract

Experimental data on the mechanics of human cornea is meager and sometimes flawed. Moreover, questions regarding the correct material symmetry and the role of the fibrous microstructure are usually glossed over when mechanical models of the cornea and corneal shape changing procedures are presented. Accordingly, the deformation of 14 intact human corneas was measured for five pressures in the physiologic range (0, 5, 10, 25 and 45 cmH2O) by tracking small, self-adherent particles placed on their anterior surfaces. The meridional strains, calculated in five regions assuming axisymmetric deformation, are small; the average strain in the apical region being 1.14% at 45 cmH2O. Results also indicate that the strain distribution is unexpectedly nonuniform with statistically significant (p < 0.01, typical) variations between regions and a minimum occurring approximately half-way between apex and limbus. To better understand these results, a finite-element model (FEM) of the cornea was constructed and used to simulate the experiment. The heterogeneous model shows that our data may reflect the changing fiber orientation along a meridian suggested in the literature. The implications of a link between microstructure and mechanics are discussed in light of clinical procedures, such as radial keratotomy, the outcomes of which are dependent on corneal mechanical properties.

Citing Articles

Corneal strain influences keratocyte proliferation and migration through upregulation of ALDH3A1 expression.

Zhang Q, Zhou X, Zhang W, Wang X, Dou S, Zhao L FASEB J. 2024; 38(23):e70236.

PMID: 39652089 PMC: 11627209. DOI: 10.1096/fj.202401392R.


Unraveling the mechanobiology of cornea: From bench side to the clinic.

Yang S, Zhang J, Tan Y, Wang Y Front Bioeng Biotechnol. 2022; 10:953590.

PMID: 36263359 PMC: 9573972. DOI: 10.3389/fbioe.2022.953590.


Comparison of penetrating femtosecond laser-assisted astigmatic keratotomy and toric intraocular lens implantation for correction of astigmatism in cataract surgery.

Noh H, Yoo Y, Shin K, Lim D, Chung T Sci Rep. 2021; 11(1):7340.

PMID: 33795782 PMC: 8016891. DOI: 10.1038/s41598-021-86763-5.


A review of corneal biomechanics: Mechanisms for measurement and the implications for refractive surgery.

Wilson A, Marshall J Indian J Ophthalmol. 2020; 68(12):2679-2690.

PMID: 33229643 PMC: 7856929. DOI: 10.4103/ijo.IJO_2146_20.


Experimental evaluation of stiffening effect induced by UVA/Riboflavin corneal cross-linking using intact porcine eye globes.

Chang S, Zhou D, Eliasy A, Li Y, Elsheikh A PLoS One. 2020; 15(11):e0240724.

PMID: 33147249 PMC: 7641398. DOI: 10.1371/journal.pone.0240724.