» Articles » PMID: 9090270

45-hour Continuous Quintuple-site Actimetry: Relations Between Trunk and Limb Movements and Effects of Circadian Sleep-wake Rhythmicity

Overview
Specialty Psychiatry
Date 1997 Mar 1
PMID 9090270
Citations 19
Authors
Affiliations
Soon will be listed here.
Abstract

Diurnal and nocturnal trunk and limb motor activity of 20 healthy individuals was evaluated by actimetry for 45 consecutive hours. Sleep was assessed by sleep logs. Overall, motor activity significantly (p < .05) decreased in the order wrist, ankle, and trunk. There was significantly more motor activity in the dominant wrist during the diurnal period. Motor activity was significantly affected by the 24-hr sleep-wake cycle, with lower levels and prolonged immobility during the night. Time series analyses revealed different but significant correlations between motor activity at all sites. These data imply that (a) motor activity should be recorded at the dominant wrist when the highest level of motor activity is of importance, (b) recordings at the nondominant wrist are better indicators of trunk movement than are dominant wrist recordings, and (c) sites other than the conventional nondominant wrist recording site should be evaluated to improve the validity of motor activity-based sleep-wake scoring.

Citing Articles

Motor and Nonmotor Measures and Declining Daily Physical Activity in Older Adults.

Oveisgharan S, Wang T, Hausdorff J, Bennett D, Buchman A JAMA Netw Open. 2024; 7(9):e2432033.

PMID: 39235807 PMC: 11378007. DOI: 10.1001/jamanetworkopen.2024.32033.


Convergent validity of time in bed estimates from activPAL and Actiwatch in free-living youth and adults.

Hibbing P, Carlson J, Simon S, Melanson E, Creasy S J Meas Phys Behav. 2024; 6(3):213-222.

PMID: 39026985 PMC: 11257610. DOI: 10.1123/jmpb.2023-0011.


The Role of Wearable Sensors to Monitor Physical Activity and Sleep Patterns in Older Adult Inpatients: A Structured Review.

Bate G, Kirk C, Rehman R, Guan Y, Yarnall A, Del Din S Sensors (Basel). 2023; 23(10).

PMID: 37430796 PMC: 10222486. DOI: 10.3390/s23104881.


Can Wearable Inertial Measurement Units Be Used to Measure Sleep Biomechanics? Establishing Initial Feasibility and Validity.

Buckley N, Davey P, Jensen L, Baptist K, Jansen B, Campbell A Biomimetics (Basel). 2023; 8(1).

PMID: 36648788 PMC: 9844380. DOI: 10.3390/biomimetics8010002.


Measuring catatonia motor behavior with objective instrumentation.

von Kanel S, Nadesalingam N, Alexaki D, Gama D, Kyrou A, Lefebvre S Front Psychiatry. 2022; 13:880747.

PMID: 36061273 PMC: 9428315. DOI: 10.3389/fpsyt.2022.880747.