Measurement of Protein Concentration of Aqueous Humour in Vivo: Correlation Between Laser Flare Measurements and Chemical Protein Determination

Overview
Specialty Ophthalmology
Date 1997 Feb 1
PMID 9088404
Citations 9
Authors
Affiliations
Soon will be listed here.
Abstract

We studied the correlation between laser flare cell meter photon count/ms and actual protein concentration both in vitro and in vivo. Laser flare cell meter measurement of human albumin concentrations of 0 to 10 g/l showed photon counts/ms from 0.3 +/- 0.3 to 78.9 +/- 3.9. There was a statistically highly significant linear correlation between photon count/ms and human albumin concentration (r = 0.98, p = 0.0001). Laser flare cell meter measurements were done on 39 cataract patients with the mean age of 77.9 +/- 6.7 years. Aqueous humour obtained by peroperative paracentesis was analysed for total protein. The mean photon count/ms before pupillary dilatation was 11.93 +/- 6.03. There was a significant linear correlation (r = 0.4, p = 0.019) between the photon count/ms after pupillary dilatation (mean 14.73 +/- 12.9, range 2.6-62.4) and anterior chamber protein concentration (mean 0.62 +/- 0.27, range 0.23-1.3 g/l) with the linear regression formula being y = 0.231 x -1.105 where y = log protein concentration (g/l) and x = log of photon count/ms. Laser flare cell meter photon counts/ms may be converted into an equivalent anterior chamber total protein concentration using this formula.

Citing Articles

Measuring Anterior Chamber Inflammation After Cataract Surgery: A Review of the Literature Focusing on the Correlation with Cystoid Macular Edema.

De Maria M, Iannetta D, Cimino L, Coassin M, Fontana L Clin Ophthalmol. 2020; 14:41-52.

PMID: 32021067 PMC: 6957928. DOI: 10.2147/OPTH.S237405.


Instrument-based tests for quantifying aqueous humour protein levels in uveitis: a systematic review protocol.

McNally T, Liu X, Beese S, Keane P, Moore D, Denniston A Syst Rev. 2019; 8(1):287.

PMID: 31771628 PMC: 6878617. DOI: 10.1186/s13643-019-1206-2.


Ocular Spot Fluorometer Equipped With a Lock-In Amplifier for Measurement of Aqueous Flare.

Sudhir R, Murthy P, Tadepalli S, Murugan S, Padmanabhan P, Krishnamurthy A Transl Vis Sci Technol. 2019; 7(6):32.

PMID: 30619652 PMC: 6314058. DOI: 10.1167/tvst.7.6.32.


Role of inflammation in previously untreated macular edema with branch retinal vein occlusion.

Noma H, Mimura T, Shimada K BMC Ophthalmol. 2014; 14:67.

PMID: 24884703 PMC: 4032564. DOI: 10.1186/1471-2415-14-67.


Long-term stability of uveitis with faint anterior chamber flare treated with once-daily topical ophthalmic betamethasone.

Kawamura M, Zako M Inflammation. 2013; 37(2):417-25.

PMID: 24114448 DOI: 10.1007/s10753-013-9754-4.