[dl-Camphor Reference Standard (Control 951) of the National Institute of Health Sciences]
Overview
Overview
Authors
Authors
Affiliations
Affiliations
Soon will be listed here.
Abstract
The raw material of dl-camphor was examined for the preparation of the "dl-Camphor Reference Standard". Analytical data obtained are as follows: ultraviolet spectrum, lambda max = 290 nm; infrared spectrum, the same as that of the present JP Camphor Reference Standard; melting point, 179.6 degrees C; purity test by gas-chromatography (GC), three kinds of impurities were detected; assay by GC, 99.0%. Based on the above results, the candidate raw material was authorized as the JP Reference Standard (Control 951).