although the waveform derived from a peripheral pulse monitor or pulse oximeter may resemble an arterial pressure waveform, it is in fact a visualization of blood volume change in transilluminated tissue caused by passage of blood: an indication of perfusion or blood flow. Most currently available pulse oximeters indicate this flow, but few display it in usable form. Since adequate tissue blood flow is a prerequisite for normal metabolic activity, it is a parameter that should merit a place in standard anesthesia or intensive care monitors. That the peripheral tissue blood flow is not routinely displayed may be in part due to the difficulty in quantifying data obtained: flow is not accurately measured as simply as pressure, even by invasive means. It is in the pattern of the waveform that beat-to-beat changes in stroke volume can be better seen than measured, or in the interaction of ventilation and circulation that tests general circulatory performance. The origin and interpretation of these changes are discussed and illustrated with examples. We indicate how new physiological tests of autonomic function and cardiac preload can be developed using pulse plethysmography. The importance and application of the Valsalva effect on the waveform is emphasized. This effect is particularly applicable for monitoring adequate fluid loading and the action of vasodilator drugs, which are both important in anesthesia. Differences between the arterial pulse pressure wave and tissue flow wave are discussed, as well as the cause of certain artifacts, including the wandering dicrotic notch.

Citing Articles

Peripheral perfusion index of pulse oximetry in adult patients: a narrative review.

Sun X, He H, Xu M, Long Y Eur J Med Res. 2024; 29(1):457.

PMID: 39261939 PMC: 11389527. DOI: 10.1186/s40001-024-02048-3.


Enhanced labor pain monitoring using machine learning and ECG waveform analysis for uterine contraction-induced pain.

Chu Y, Chen S, Chen K, Sun J, Shen T, Chen L BioData Min. 2024; 17(1):32.

PMID: 39243100 PMC: 11380346. DOI: 10.1186/s13040-024-00383-z.


A new method of continuous blood pressure monitoring using multichannel sensing signals on the wrist.

Wang L, Tian S, Zhu R Microsyst Nanoeng. 2023; 9:117.

PMID: 37744263 PMC: 10511443. DOI: 10.1038/s41378-023-00590-4.


The Principles of Hearable Photoplethysmography Analysis and Applications in Physiological Monitoring-A Review.

Azudin K, Beng Gan K, Jaafar R, Jaafar M Sensors (Basel). 2023; 23(14).

PMID: 37514778 PMC: 10384007. DOI: 10.3390/s23146484.


Advances in Cuffless Continuous Blood Pressure Monitoring Technology Based on PPG Signals.

Qin C, Wang X, Xu G, Ma X Biomed Res Int. 2022; 2022:8094351.

PMID: 36217389 PMC: 9547685. DOI: 10.1155/2022/8094351.


References
1.
Severinghaus J, Kelleher J . Recent developments in pulse oximetry. Anesthesiology. 1992; 76(6):1018-38. DOI: 10.1097/00000542-199206000-00024. View

2.
Savoia G, Esposito C, Belfiore F, Amantea B, Cuocolo R . Propofol infusion and auditory evoked potentials. Anaesthesia. 1988; 43 Suppl:46-9. DOI: 10.1111/j.1365-2044.1988.tb09069.x. View

3.
ORourke M, Yaginuma T . Wave reflections and the arterial pulse. Arch Intern Med. 1984; 144(2):366-71. View

4.
SHARPEY-SCHAFER E . Effects of coughing on intrathoracic pressure, arterial pressure and peripheral blood flow. J Physiol. 1953; 122(2):351-7. PMC: 1366120. DOI: 10.1113/jphysiol.1953.sp005004. View

5.
James D, Brown Jr R . Vascular volume monitoring with pulse oximetry during paediatric anaesthesia. Can J Anaesth. 1990; 37(2):266-7. DOI: 10.1007/BF03005484. View