Heart Rate Affects the Dependency of Myocardial Oxygen Consumption on Flow in Goats

Overview
Journal Heart Vessels
Date 1995 Jan 1
PMID 8904001
Citations 2
Authors
Affiliations
Soon will be listed here.
Abstract

The effect of flow steps in coronary arterial flow (Qa) on myocardial oxygen consumption (MVo2) was investigated at different heart rates (HR) to further elucidate the dependency of myocardial oxygen consumption on perfusion. In six anesthetized goats the left main coronary artery and the great cardiac vein were cannulated. The hearts were paced alternately at 60 and 130 beats per min. Flow steps were applied at both HR during control and maximal vasodilation by adenosine. MVo2, in steady state before and after the flow step, was calculated by multiplication of Qa and arterio-venous oxygen content difference (Fick's law). Heart rate affected the MVo2 dependency on flow during control as well as during maximal vasodilation. With vascular tone present, the MVo2 dependency on flow (DeltaMVo2/DeltaQa), in mu l O2/ml, was 16.0 +/- 3.6 at HR 60 and 21.7 +/- 3.9 at HR 130. During maximal vasodilation, these values were 9.5 +/- 2.9 and 17.0 +/- 5.3 at HR 60 and 130, respectively. The higher MVo2 dependency on flow at high HR may be explained via a dependency of MVo2 on microvascular pressure. The pressure change in the microvessels induced by a flow step is probably larger at high HR than at low HR because of increased venous resistance at high HR, due to increased compression by the heart contraction.

Citing Articles

Anomalous Aortic Origin of the Right Coronary Artery: Invasive Haemodynamic Assessment in Adult Patients With High-Risk Anatomic Features.

Verheijen D, Egorova A, Jongbloed M, van der Kley F, Koolbergen D, Hazekamp M CJC Pediatr Congenit Heart Dis. 2023; 2(3):124-133.

PMID: 37969355 PMC: 10642095. DOI: 10.1016/j.cjcpc.2023.03.001.


Disentangling the Gordian knot of local metabolic control of coronary blood flow.

Tune J, Goodwill A, Kiel A, Baker H, Bender S, Merkus D Am J Physiol Heart Circ Physiol. 2019; 318(1):H11-H24.

PMID: 31702972 PMC: 7199237. DOI: 10.1152/ajpheart.00325.2019.

References
1.
Spaan J, Breuls N, Laird J . Diastolic-systolic coronary flow differences are caused by intramyocardial pump action in the anesthetized dog. Circ Res. 1981; 49(3):584-93. DOI: 10.1161/01.res.49.3.584. View

2.
Kitakaze M, Marban E . Cellular mechanism of the modulation of contractile function by coronary perfusion pressure in ferret hearts. J Physiol. 1989; 414:455-72. PMC: 1189152. DOI: 10.1113/jphysiol.1989.sp017698. View

3.
Arnold G, Kosche F, Miessner E, Neitzert A, LOCHNER W . The importance of the perfusion pressure in the coronary arteries for the contractility and the oxygen consumption of the heart. Pflugers Arch Gesamte Physiol Menschen Tiere. 1968; 299(4):339-56. DOI: 10.1007/BF00602910. View

4.
RAKUSAN K . Vascular capacity and hematocrit in experimental cardiomegaly due to aortic constriction in rats. Can J Physiol Pharmacol. 1971; 49(9):819-23. View

5.
Bers D . Early transient depletion of extracellular Ca during individual cardiac muscle contractions. Am J Physiol. 1983; 244(3):H462-8. DOI: 10.1152/ajpheart.1983.244.3.H462. View