» Articles » PMID: 8869173

Anterior Fontanelle Pressure Monitoring for the Evaluation of Asymptomatic Infants with Increased Head Growth Rate

Overview
Specialty Pediatrics
Date 1996 Jan 1
PMID 8869173
Citations 2
Authors
Affiliations
Soon will be listed here.
Abstract

We studied non-invasive intracranial pressure monitoring in 20 asymptomatic infants with increased head growth rate. Both basal anterior fontanelle pressure (AFP) traces and occurrence of pressure waves were analysed and compared with normal range values previously established. Eight recordings were classified as pathological; cerebral imaging showed subdural collections or ventricular dilatation in all cases. Five out of these eight infants further developed neurological deficits and/or increase of the ventricular size, and required neurosurgical procedures. Twelve infants had normal AFP traces; six of these had normal cerebral imaging and six showed enlargement of subarachnoid spaces with normal ventricles. All of these 12 patients normalised their head growth rate and remained asymptomatic. This observation suggests that AFP monitoring may be helpful in asymptomatic infants with increased head growth rate to identify a progressive intracranial process and the potential need for a neurosurgical procedure.

Citing Articles

Wearable Intracranial Pressure Monitoring Sensor for Infants.

Zhang B, Huang Z, Song H, Kim H, Park J Biosensors (Basel). 2021; 11(7).

PMID: 34210050 PMC: 8301997. DOI: 10.3390/bios11070213.


A comprehensive review of the anterior fontanelle: embryology, anatomy, and clinical considerations.

DAntoni A, Donaldson O, Schmidt C, Macchi V, De Caro R, Oskouian R Childs Nerv Syst. 2017; 33(6):909-914.

PMID: 28396968 DOI: 10.1007/s00381-017-3406-1.

References
1.
Raftopoulos C, Chaskis C, Delecluse F, Cantraine F, Bidaut L, Brotchi J . Morphological quantitative analysis of intracranial pressure waves in normal pressure hydrocephalus. Neurol Res. 1992; 14(5):389-96. DOI: 10.1080/01616412.1992.11740091. View

2.
Azais M, Echenne B . [Idiopathic pericerebral swelling (external hydrocephalus) of infants]. Ann Pediatr (Paris). 1992; 39(9):550-8. View

3.
Wayenberg J, Raftopoulos C, Vermeylen D, Pardou A . Non-invasive measurement of intracranial pressure in the newborn and the infant: the Rotterdam teletransducer. Arch Dis Child. 1993; 69(5 Spec No):493-7. PMC: 1029591. DOI: 10.1136/adc.69.5_spec_no.493. View

4.
Hill A, Volpe J . Measurement of intracranial pressure using the Ladd intracranial pressure monitor. J Pediatr. 1981; 98(6):974-6. DOI: 10.1016/s0022-3476(81)80608-7. View

5.
de Jong D, Maas A, v d Voort E . Non-invasive intracranial pressure monitoring. A technique for reproducible fontanelle pressure measurements. Z Kinderchir. 1984; 39(4):274-6. DOI: 10.1055/s-2008-1044227. View