» Articles » PMID: 8679029

Radiographic Sizing for Meniscal Transplantation

Overview
Journal Arthroscopy
Specialty Orthopedics
Date 1995 Dec 1
PMID 8679029
Citations 79
Authors
Affiliations
Soon will be listed here.
Abstract

Allograft or synthetic meniscal replacement has the potential to delay the arthritic sequelae of the meniscectomized knee. Meniscal implants must, however, be side and size specific. A cadaveric study was performed in which medial and lateral menisci were painted with a radiopaque tantalum powder-cyanoacrylic mixture. Radiographs of this preparation demonstrated reproducible relationships between each meniscus and established bony landmarks. When corrected for magnification, meniscal size could be derived from plain films. Meniscal width equaled the distance (coronal) from the peak of the tibial eminence to the periphery of the tibial metaphysis on anteroposterior films. Meniscal length was measured from lateral radiographs. Medial meniscal length was 80%, and lateral meniscal length was 70% of the measured sagittal length of the tibial plateau. Measurement error averaged 7.8% by these parameters.

Citing Articles

Thickness and width of the menisci of adult knee joint: a descriptive cross-sectional observational study in cadavers.

Murlimanju B, Vikram S, Nayak V, Bhat N, Pai M, Vadgaonkar R F1000Res. 2024; 11:1573.

PMID: 38725543 PMC: 11079982. DOI: 10.12688/f1000research.128395.2.


A narrative review of lateral meniscus transplantation with the bridge in slot: technique and outcomes.

Nathan L, Kester B, Condron N, Evuarherhe Jr A, Cole B Ann Jt. 2024; 7:17.

PMID: 38529142 PMC: 10929392. DOI: 10.21037/aoj-20-109.


Single-incision bone bridge lateral meniscus allograft transplantation: preserving neurovascular safety with promising results for posterior horn distortion and graft maturation.

Lee J, Lee D, Kyeong T, Lee J, Kim J Knee Surg Sports Traumatol Arthrosc. 2023; 31(12):5864-5872.

PMID: 37964127 DOI: 10.1007/s00167-023-07641-3.


Unique Anatomical Features of the Discoid Lateral Meniscus via Three-Dimensional MRI.

Nekomoto A, Ishikawa M, Tsuji S, Shimamura Y, Kitamura N, Kamei G Cureus. 2023; 15(9):e46188.

PMID: 37905280 PMC: 10613346. DOI: 10.7759/cureus.46188.


Meniscus Size Differs Between Patient and Donor Populations for Meniscus Allograft Transplantation.

Tabbaa S, Pace J, Frank R, Grammens J, Verdonk P Arthrosc Sports Med Rehabil. 2023; 5(3):e569-e576.

PMID: 37388864 PMC: 10300528. DOI: 10.1016/j.asmr.2023.02.009.