» Articles » PMID: 8653947

Radioactive Synoviorthesis in Hemophilic Hemarthrosis: Materials, Techniques, and Dangers

Overview
Publisher Wolters Kluwer
Specialty Orthopedics
Date 1996 Jul 1
PMID 8653947
Citations 7
Authors
Affiliations
Soon will be listed here.
Abstract

Radioactive synoviorthesis with 198Au, 90Y, 186Re, and 31P would seem to be the treatment of choice for recurrent hemarthroses in hemophilia. The clinical results, obtained by different centers, show a definite diminution of hemarthroses in 88% of cases. The advantages of radioactive synoviorthesis compared with surgical synovectomy are: better results, the requirement of substantially reduced antihemophilic factor, the possibility of performing the procedure on multiple cases concurrently on an ambulatory basis, no interference with articular range of movement, and the low cost of the procedure. In cases of failure, the procedure can be repeated after 6 months, and on as many as 3 occasions. Studies performed on the chromosomal changes that could be attributed to the radioactive material show the disappearance of these alterations a few years after treatment. No physical changes have been found that could be attributed to cytogenic alteration (hematologic or other) in any reported patients.

Citing Articles

Synovectomy using Samarium-153 Hydroxyapatite in the Elbows and Ankles of Patients with Hemophilic Arthropathy.

Calegaro J, Haje D, Machado J, Sayago M, de Landa D World J Nucl Med. 2018; 17(1):6-11.

PMID: 29398959 PMC: 5778719. DOI: 10.4103/wjnm.WJNM_91_16.


Radiosynoviorthesis in hemophilic arthropathy: pathologic blood pool imaging on pre-therapeutic bone scintigraphy is not a predictor of treatment success.

Sabet A, Strauss A, Schmolders J, Bornemann R, Sabet A, Oldenburg J Eur J Nucl Med Mol Imaging. 2016; 44(3):461-467.

PMID: 27796541 DOI: 10.1007/s00259-016-3549-4.


Effects of intraarticular (32)P colloid in the treatment of hemophilic synovitis of the knee: A short term clinical study.

Zhang W, Han S, Yuan Z, He Y, Zhang H, Zhang M Indian J Orthop. 2016; 50(1):55-8.

PMID: 26955177 PMC: 4759875. DOI: 10.4103/0019-5413.173507.


The efficacy of magnetic resonance imaging and x-ray in the evaluation of response to radiosynovectomy in patients with hemophilic arthropathy.

Ozulker T, Ozulker F, Derin E, Altun M, Aydogan G, Turkkan E Mol Imaging Radionucl Ther. 2013; 20(2):38-44.

PMID: 23487524 PMC: 3590945. DOI: 10.4274/MIRT.25.


Consecutive radiosynovectomy procedures at 6-monthly intervals behave independently in haemophilic synovitis.

De la Corte-Rodriguez H, Rodriguez-Merchan E, Jimenez-Yuste V Blood Transfus. 2012; 11(2):254-9.

PMID: 23245712 PMC: 3626478. DOI: 10.2450/2012.0099-12.