» Articles » PMID: 8649916

The Significance of Sweat Cl/Na Ratio in Patients with Borderline Sweat Test

Overview
Date 1995 Dec 1
PMID 8649916
Citations 7
Authors
Affiliations
Soon will be listed here.
Abstract

Recently a few cystic fibrosis (CF) patients with borderline or normal sweat tests have been reported. These patients present a diagnostic challenge. We aimed to study the sweat Cl/Na ratio in cystic fibrosis patients and to assess whether this ratio could be used as a diagnostic criteria. The mean sweat Cl/Na ratio of 3 groups was compared: Group A: 71 CF patients carrying 2 mutations known to be associated with severe disease presentation (delta F508, W1282X, G542X, N1303K, 1717-1G --> A). Group B: 10 compound heterozygous patients who carry one mutation associated with mild clinical disease (3849 + 10 kb --> T). Group C: 142 normal subjects. Sweat chloride levels higher than those of sodium were found in 96% of patients in Group A as compared to 3% of patients in Group C. In Group B 40% of the patients had sweat chloride levels higher than or equal to sodium levels. The mean Cl/Na ratio of Group A (1.2 +/- 0.1) differed significantly from that of Group B (0.94 +/- 0.1) and both groups had significant higher mean Cl/Na ratio compared to Group C (0.7 +/- 0.4) (P < 0.001). Thus in individuals with a borderline sweat test and a Cl/Na ratio > or = 1 the diagnosis of CF should be considered. However, a Cl/Na ratio < 1 does not exclude CF, since patients carrying mild mutations may have sweat sodium levels higher than those of chloride. Our findings suggest that the sweat Cl/Na ratio in CF is genetically determined and it may be of help in establishing the diagnosis of CF in patients with a borderline sweat test.

Citing Articles

Wearable microfluidic-based e-skin sweat sensors.

Tabasum H, Gill N, Mishra R, Lone S RSC Adv. 2022; 12(14):8691-8707.

PMID: 35424805 PMC: 8985157. DOI: 10.1039/d1ra07888g.


Skin-Integrated Wearable Systems and Implantable Biosensors: A Comprehensive Review.

Rodrigues D, Barbosa A, Rebelo R, Kwon I, Reis R, Correlo V Biosensors (Basel). 2020; 10(7).

PMID: 32708103 PMC: 7400150. DOI: 10.3390/bios10070079.


The Dynamic Response of Sweat Chloride to Changes in Exercise Load Measured by a Wearable Sweat Sensor.

Choi D, Kitchen G, Stewart K, Searson P Sci Rep. 2020; 10(1):7699.

PMID: 32382047 PMC: 7205967. DOI: 10.1038/s41598-020-64406-5.


Wearable Potentiometric Sensors for Medical Applications.

Cuartero M, Parrilla M, Crespo G Sensors (Basel). 2019; 19(2).

PMID: 30658434 PMC: 6359219. DOI: 10.3390/s19020363.


Skin-interfaced systems for sweat collection and analytics.

Choi J, Ghaffari R, Baker L, Rogers J Sci Adv. 2018; 4(2):eaar3921.

PMID: 29487915 PMC: 5817925. DOI: 10.1126/sciadv.aar3921.