Performance Characteristics of Hemox-Analyzer for Assessment of the Hemoglobin Dissociation Curve

Overview
Journal Haematologica
Specialty Hematology
Date 1995 Sep 1
PMID 8566883
Citations 29
Authors
Affiliations
Soon will be listed here.
Abstract

The Hemox-Analyzer (TCS, Medical Products Division, Southampton, PA) is an automatic system for determining the oxyhemoglobin dissociation curve (ODC) and P50 values. The ODC is recorded during deoxygenation with nitrogen gas and plotted on graph paper; the oxygen tension is detected by a Clark electrode, while the oxyhemoglobin fraction (%HbO2) is evaluated by a dual-wavelength spectrophotometer. Even though this instrument has been commercially available for more than 20 years, its performance characteristics have been assessed. We evaluated the performance characteristics of the Hemox-Analyzer. P50 was tested in 28 healthy volunteers, in 16 anemic and in 9 polycythemic patients. To test its precision we evaluated both inter- and intra-assay variability. The system shows good precision: standard deviation was 0.39 for assays in duplicate, CV = 1.9% for intra-assay and CV = 3.0% for inter-assay measurements. The mean P50 values were 25.2 +/- 1.5 mmHg in normal volunteers and 27.3 +/- 1.4 mmHg in anemic patients. The Hemox-Analyzer is a simple, quick and reliable instrument for recording the oxyhemoglobin dissociation curve. Both the P50 value and observation of the fine structure of the curve can furnish information about the delivery of oxygen to tissues.

Citing Articles

Exposure of cryopreserved red cell concentrates to real-world transient warming events has a negligible impact on quality.

Kurach J, Brandon-Coatham M, Olafson C, Turner T, Phan C, Yazdanbakhsh M Transfusion. 2024; 64(12):2353-2363.

PMID: 39485279 PMC: 11637290. DOI: 10.1111/trf.18054.


Altered RBC deformability in diabetes: clinical characteristics and RBC pathophysiology.

Ebenuwa I, Violet P, Tu H, Lee C, Munyan N, Wang Y Cardiovasc Diabetol. 2024; 23(1):370.

PMID: 39425096 PMC: 11490132. DOI: 10.1186/s12933-024-02453-2.


Commentary: COVID-19 impairs oxygen delivery by altering red blood cell hematological, hemorheological, and oxygen transport properties.

Boning D, Bloch W, Vogel D, Steinach M, Kuebler W Front Physiol. 2024; 15:1426505.

PMID: 39318367 PMC: 11420525. DOI: 10.3389/fphys.2024.1426505.


Impact of cold storage on the oxygenation and oxidation reactions of red blood cells.

Kassa T, Jana S, Baek J, Alayash A Front Physiol. 2024; 15:1427094.

PMID: 39224206 PMC: 11366621. DOI: 10.3389/fphys.2024.1427094.


DAHEAN: A Danish nationwide study ensuring quality assurance through real-world data for suspected hereditary anemia patients.

Glenthoj A, Rasmussen A, Bendtsen S, Hasle H, Hoffmann M, Rieneck K Orphanet J Rare Dis. 2024; 19(1):284.

PMID: 39085840 PMC: 11290079. DOI: 10.1186/s13023-024-03298-4.