» Articles » PMID: 8536727

Multicenter Evaluation of a New Commercial Assay for Detection of Immunoglobulin M Antibodies to Toxoplasma Gondii. Multicenter Study Group

Overview
Publisher Springer
Date 1995 Sep 1
PMID 8536727
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

A new commercial assay for detection of IgM-specific antibodies to Toxoplasma gondii (IMx Toxo IgM, Abbott, USA), based on microparticle enzyme immunoassay technology, was evaluated at 15 clinical sites in Europe and the USA. Performance characteristics were established by testing clinical specimens collected randomly from pregnant women, blood donors, individuals with suspected Toxoplasma gondii infection and individuals confirmed HIV positive. Reference testing was performed using Toxo-M EIA (Abbott). Specimens evaluated at European sites yielding discordant results between the new assay and the reference EIA were further tested with an immunosorbent agglutination assay; at sites in the USA, discordant results were resolved using Platelia Toxo IgM (Sanofi, France) and Vidas Toxo IgM (bioMérieux, France) assays. In addition, matched plasma and serum, heat-treated and non-heat-treated specimens, and fresh and frozen specimens were evaluated at the USA sites. At European sites the new commercial assay had a sensitivity of 95.6% (196/205), a specificity of 99.8% (3,137/3,143) and an agreement of 99.6% (3,333/3,348) following resolution of discordant results; sensitivity in the USA was 97.4% (184/189), specificity was 99.8% (1,204/1,207) and agreement was 99.4% (1,388/1,396) following resolution. The new IMx Toxo IgM is a sensitive and specific assay for measurement of IgM antibodies to Toxoplasma gondii in human serum and plasma.

Citing Articles

Sero-prevalence of toxoplasmosis in pregnant mothers and new born infants in eastern province, saudi arabia.

Al-Mulhim A, Al-Qurashi A J Family Community Med. 2012; 8(1):45-8.

PMID: 23008638 PMC: 3437067.


The probability of acquiring primary Toxoplasma infection in HIV-infected patients: results of an 8-year retrospective study.

Reiter-Owona I, Bialek R, Rockstroh J, Seitz H Infection. 1998; 26(1):20-5.

PMID: 9505175 DOI: 10.1007/BF02768747.


Evaluation of six commercial kits for detection of human immunoglobulin M antibodies to Toxoplasma gondii. The FDA Toxoplasmosis Ad Hoc Working Group.

Wilson M, Remington J, Clavet C, Varney G, Press C, Ware D J Clin Microbiol. 1997; 35(12):3112-5.

PMID: 9399504 PMC: 230132. DOI: 10.1128/jcm.35.12.3112-3115.1997.


Evaluation of the second generation IMx Toxo IgG antibody assay for detection of antibodies to Toxoplasma gondii in human sera.

De Champs C, Pelloux H, Cambon M, Fricker-Hidalgo H, Goullier-Fleuret A, Ambroise-Thomas P J Clin Lab Anal. 1997; 11(4):214-9.

PMID: 9219063 PMC: 6760745. DOI: 10.1002/(sici)1098-2825(1997)11:4<214::aid-jcla7>3.0.co;2-8.


False-positive results in immunoglobulin M (IgM) toxoplasma antibody tests and importance of confirmatory testing: the Platelia Toxo IgM test.

Liesenfeld O, Press C, Montoya J, Gill R, Hedman K, Remington J J Clin Microbiol. 1997; 35(1):174-8.

PMID: 8968902 PMC: 229533. DOI: 10.1128/jcm.35.1.174-178.1997.


References
1.
Pinon J, Poirriez J, Leroux B, Dupouy D, Quereux C, GARIN J . [Early diagnosis and surveillance of congenital toxoplasmosis. The comparative immunological profiles method]. Presse Med. 1987; 16(10):471-4. View

2.
Bessieres M, Roques C, Berrebi A, Barre V, Cazaux M, Seguela J . IgA antibody response during acquired and congenital toxoplasmosis. J Clin Pathol. 1992; 45(7):605-8. PMC: 495188. DOI: 10.1136/jcp.45.7.605. View

3.
Johnson A, Roberts H, Tenter A . Evaluation of a recombinant antigen ELISA for the diagnosis of acute toxoplasmosis and comparison with traditional antigen ELISAs. J Med Microbiol. 1992; 37(6):404-9. DOI: 10.1099/00222615-37-6-404. View

4.
McCabe R, Remington J . The diagnosis and treatment of toxoplasmosis. Eur J Clin Microbiol. 1983; 2(2):95-104. DOI: 10.1007/BF02001573. View

5.
Braun R, Doerr H, Geisen H, Hornig C, Huschka U, Munk K . Comparison of different methods for the detection of rubella-specific IgM antibodies. J Med Virol. 1981; 8(3):207-14. DOI: 10.1002/jmv.1890080308. View