» Articles » PMID: 8425366

Determining the Rotational Alignment of the Femoral Component in Total Knee Arthroplasty Using the Epicondylar Axis

Overview
Publisher Wolters Kluwer
Specialty Orthopedics
Date 1993 Jan 1
PMID 8425366
Citations 215
Authors
Affiliations
Soon will be listed here.
Abstract

The posterior condylar surfaces of the femur are routinely used as the reference for the rotational orientation of the femoral component during most primary total knee arthroplasties. The purpose of this investigation was to identify a clearly discernible, reproducible secondary anatomic axis useful for determining the rotational orientation of the femoral component when the posterior condylar surfaces cannot be used. Seventy-five embalmed anatomic specimen femurs were studied. A surgical epicondylar axis was defined as the line connecting the lateral epicondylar prominence and the medial sulcus of the medial epicondyle. The posterior condylar angle was measured as the angle between the posterior condylar surfaces and the surgical epicondylar axis. Measurement of the posterior condylar angle referenced from the surgical epicondylar axis yielded a mean posterior condylar angle of 3.5 degrees (+/- 1.2 degrees) of internal rotation for males and a mean posterior condylar angle of 0.3 degree (+/- 1.2 degrees) of internal rotation for females. Thus, rotational alignment of the femoral component can be accurately estimated using the posterior condylar angle. The posterior condylar angle, referenced from the surgical epicondylar axis, provides a visual rotational alignment check during primary arthroplasty and may improve alignment of the femoral component at revision.

Citing Articles

The Role of Computed Tomography in Achieving True External Rotation in Robotic Knee Replacement: A Retrospective Analysis of 300 Knees.

Bhor P, Pawar S, Ali S, Vatkar A, Kale S, Kutumbe D J Orthop Case Rep. 2025; 15(2):269-274.

PMID: 39957918 PMC: 11823844. DOI: 10.13107/jocr.2025.v15.i02.5304.


Characteristics of Resection Parameters in Robot-Assisted Total Knee Arthroplasty With the Ligament Balancing Workflow.

Wei Q, An H, Gu W, Sun W, Li R, Chai W Orthop Surg. 2025; 17(3):841-847.

PMID: 39846233 PMC: 11872359. DOI: 10.1111/os.14336.


A reproducible representation of healthy tibiofemoral kinematics during stair descent using REFRAME - part I: REFRAME foundations and validation.

Ortigas-Vasquez A, Taylor W, Postolka B, Schutz P, Maas A, Woiczinski M Sci Rep. 2025; 15(1):2276.

PMID: 39824984 PMC: 11742382. DOI: 10.1038/s41598-025-86137-1.


Dorsal cortex line is more reliable than transepicondylar axis for rotation in revision total knee arthroplasty with severe bone loss.

Salzmann M, Kropp E, Prill R, Ramadanov N, Adriani M, Becker R Bone Jt Open. 2024; 5(12):1067-1071.

PMID: 39617032 PMC: 11608806. DOI: 10.1302/2633-1462.512.BJO-2024-0140.R1.


A reproducible representation of healthy tibiofemoral kinematics during stair descent using REFRAME - Part II: Exploring optimisation criteria and inter-subject differences.

Ortigas-Vasquez A, Taylor W, Postolka B, Schutz P, Maas A, Grupp T Sci Rep. 2024; 14(1):25345.

PMID: 39455805 PMC: 11511945. DOI: 10.1038/s41598-024-76275-3.