» Articles » PMID: 8414753

MIBG Detection of Hepatic Neuroblastoma: Correlation with CT, US and Surgical Findings

Overview
Journal Pediatr Radiol
Specialty Pediatrics
Date 1993 Jan 1
PMID 8414753
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

Metaiodobenzylguanidine (MIBG) imaging is used in the diagnosis, staging and follow-up of virtually every case of neuroblastoma seen at our institution. Normal sites of MIBG uptake include the liver and therefore difficulties have been predicted and encountered in the diagnosis of hepatic neuroblastoma due to inability to separate abnormally increased tracer deposition from normal hepatic activity. We reviewed every MIBG (I123 and I131) study performed at our pediatric hospital over a 4 year period encompassing 88 patients, 67 of whom had biopsy proven neuroblastoma. Hepatic findings onMIBG studies were compared with concurrent abdominal CT and US studies in all 67 patients. The clinical records of all patients with abnormal MIBG scans or abnormal CT or US studies of the liver were also reviewed. Eight patients were found to have abnormal liver findings on one or more imaging studies (MIBG, CT, or US). There were 3 true positive MIBG studies, one of which was an early study in a patient who later went on to have one of the false positive studies. Two patients had false positive MIBG scans for liver neuroblastoma. MIBG failed to detect liver involvement in 4 patients.

Citing Articles

Value of SPECT/CT in Diagnostic I-131 MIBG Scintigraphy in Patients with Neuroblastoma.

Theerakulpisut D, Raruenrom Y, Wongsurawat N, Somboonporn C Nucl Med Mol Imaging. 2018; 52(5):350-358.

PMID: 30344783 PMC: 6177351. DOI: 10.1007/s13139-018-0532-y.


123I-MIBG scintigraphy and 18F-FDG-PET imaging for diagnosing neuroblastoma.

Bleeker G, Tytgat G, Adam J, Caron H, Kremer L, Hooft L Cochrane Database Syst Rev. 2015; (9):CD009263.

PMID: 26417712 PMC: 4621955. DOI: 10.1002/14651858.CD009263.pub2.


Imaging the norepinephrine transporter in neuroblastoma: a comparison of [18F]-MFBG and 123I-MIBG.

Zhang H, Huang R, Cheung N, Guo H, Zanzonico P, Thaler H Clin Cancer Res. 2014; 20(8):2182-91.

PMID: 24573553 PMC: 4072734. DOI: 10.1158/1078-0432.CCR-13-1153.


123I MIBG mapping with intraoperative gamma probe for recurrent neuroblastoma.

Iagaru A, Peterson D, Quon A, Dutta S, Twist C, Daghighian F Mol Imaging Biol. 2007; 10(1):19-23.

PMID: 17975716 DOI: 10.1007/s11307-007-0116-1.


Neuroblastoma as a neurobiological disease.

Schor N J Neurooncol. 1999; 41(2):159-66.

PMID: 10222436 DOI: 10.1023/a:1006171406740.


References
1.
Lumbroso J, Guermazi F, Hartmann O, Coornaert S, Rabarison Y, Leclere J . Meta-iodobenzylguanidine (mIBG) scans in neuroblastoma: sensitivity and specificity, a review of 115 scans. Prog Clin Biol Res. 1988; 271:689-705. View

2.
Geatti O, Shapiro B, Sisson J, Hutchinson R, Mallette S, Eyre P . Iodine-131 metaiodobenzylguanidine scintigraphy for the location of neuroblastoma: preliminary experience in ten cases. J Nucl Med. 1985; 26(7):736-42. View

3.
Nakajo M, Shapiro B, Copp J, Kalff V, Gross M, Sisson J . The normal and abnormal distribution of the adrenomedullary imaging agent m-[I-131]iodobenzylguanidine (I-131 MIBG) in man: evaluation by scintigraphy. J Nucl Med. 1983; 24(8):672-82. View