Plasma Concentrations of Bupivacaine After Wound Infiltration of an 0.5% Solution After Inguinal Herniorrhaphy: a Preliminary Study
Overview
Affiliations
After routine inguinal herniorrhaphy we gave 12 patients a wound infiltration regimen of bolus doses of 20 ml of 0.5% bupivacaine via a catheter within the wound and rectally administered indomethacin (100 mg). Peak venous plasma bupivacaine concentrations ranged from 0.07 mg.l-1 to 1.14 mg.l-1 (mean (SD) 0.47 (0.33) mg.l-1), and occurred at between 0.25 and 2 h after the first dose. Plasma concentrations were well below the toxic threshold of 4 mg.l-1 and there was no accumulation. The regimen provided satisfactory analgesia. There were no wound infections nor signs of toxicity.
Ben-Saghroune H, Abdessadek M, Achour S, Kfal Y, El Bouazzaoui A, Kanjaa N Anesthesiol Res Pract. 2023; 2023:8842393.
PMID: 37854305 PMC: 10581849. DOI: 10.1155/2023/8842393.
Chung D, Lee Y, Jo M, Park H, Lim G, Cho H Obstet Gynecol Sci. 2013; 56(2):93-101.
PMID: 24327987 PMC: 3784090. DOI: 10.5468/OGS.2013.56.2.93.
Cusack S, Reginald P, Hemsen L, Umerah E J Pain Res. 2013; 6:151-9.
PMID: 23503706 PMC: 3594918. DOI: 10.2147/JPR.S40976.
Hu D, Onel E, Singla N, Kramer W, Hadzic A Clin Drug Investig. 2012; 33(2):109-15.
PMID: 23229686 DOI: 10.1007/s40261-012-0043-z.
Bulut T, Yilmazlar A, Yavascaoglu B, Sarisozen B J Child Orthop. 2012; 5(3):179-85.