» Articles » PMID: 8188897

Assessment of Cerebral Blood Volume with Dynamic Susceptibility Contrast Enhanced Gradient-echo Imaging

Overview
Specialty Radiology
Date 1994 May 1
PMID 8188897
Citations 15
Authors
Affiliations
Soon will be listed here.
Abstract

Objective: Dynamic susceptibility contrast (DSC) enhanced MRI was used to study relative cerebral blood volume (rCBV).

Materials And Methods: We examined 15 healthy subjects and 47 patients with vascular stenosis or occlusion, with brain infarctions, and with cerebral neoplasms. During bolus injection of Gd-diethylenetriamine pentaacetic acid, a series of rapid T2*-weighted fast low angle shot two-dimensional images were recorded from the same slice. From these images, changes in signal intensity during bolus passage were computed pixel-by-pixel and converted into contrast agent concentration curves. Applying the principles of indicator dilution theory, images of rCBV were calculated.

Results And Conclusion: Regions of infarctions show almost zero rCBV. In patients with high-grade vascular stenosis or occlusion a bolus delay in comparison to the unaffected side and an increased mean transit time can be observed. Some of the affected areas show an increased rCBV, which is a well-known physiological mechanism that takes place to compensate for the reduced cerebral blood pressure. In brain tumors, rCBV imaging reveals focal or homogeneous areas of increased blood volume. This can even be observed in low-grade astrocytomas with unaffected blood-brain barrier. In CBV imaging, the effects of radiotherapy on tumor tissue can be monitored as a significant decrease of rCBV in tumor tissue after therapy.

Citing Articles

Three-Dimensional Iron Oxide Nanoparticle-Based Contrast-Enhanced Magnetic Resonance Imaging for Characterization of Cerebral Arteriogenesis in the Mouse Neocortex.

de Bortoli T, Boehm-Sturm P, Koch S, Nieminen-Kelha M, Wessels L, Mueller S Front Neurosci. 2021; 15:756577.

PMID: 34899163 PMC: 8662986. DOI: 10.3389/fnins.2021.756577.


Combined spin- and gradient-echo perfusion-weighted imaging.

Schmiedeskamp H, Straka M, Newbould R, Zaharchuk G, Andre J, Olivot J Magn Reson Med. 2011; 68(1):30-40.

PMID: 22114040 PMC: 3374915. DOI: 10.1002/mrm.23195.


Robustness of quantitative compressive sensing MRI: the effect of random undersampling patterns on derived parameters for DCE- and DSC-MRI.

Smith D, Li X, Gambrell J, Arlinghaus L, Quarles C, Yankeelov T IEEE Trans Med Imaging. 2011; 31(2):504-11.

PMID: 22010146 PMC: 3289060. DOI: 10.1109/TMI.2011.2172216.


Assessment of therapeutic response and treatment planning for brain tumors using metabolic and physiological MRI.

Nelson S NMR Biomed. 2011; 24(6):734-49.

PMID: 21538632 PMC: 3772179. DOI: 10.1002/nbm.1669.


Absolute quantification of perfusion using dynamic susceptibility contrast MRI: pitfalls and possibilities.

Knutsson L, Stahlberg F, Wirestam R MAGMA. 2009; 23(1):1-21.

PMID: 19960361 DOI: 10.1007/s10334-009-0190-2.