Abstract

We describe a new method for the reconstruction of ruptures of the patellar ligament or the quadriceps tendon, using the flexible open-weave polyester Leeds-Keio prosthetic ligament. Of 25 operations performed since 1985, we were able to review 18 patients (19 knees) with a mean follow-up of 3.5 years (3 to 6.5). No patient had required immobilisation of the knee after operation and the average period to return to normal activities without a walking aid was 10.5 weeks. The average range of motion was 146 degrees, and four patients could squat fully in the Japanese style. There was an extension lag (< 10 degrees) in only four patients; eight patients had some patellar crepitus which was mildly painful in three. There were no cases of infection, persistent joint effusion or rerupture of the extensor apparatus.

Citing Articles

Bio-Enhanced Neoligaments Graft Bearing FE002 Primary Progenitor Tenocytes: Allogeneic Tissue Engineering & Surgical Proofs-of-Concept for Hand Ligament Regenerative Medicine.

Jeannerat A, Meuli J, Peneveyre C, Jaccoud S, Chemali M, Thomas A Pharmaceutics. 2023; 15(7).

PMID: 37514060 PMC: 10385025. DOI: 10.3390/pharmaceutics15071873.


Characteristics of multi-ligament knee injuries accompanied with patellar tendon disruption.

Chun Y, Kim S, Lee S Eur J Trauma Emerg Surg. 2023; 49(4):1821-1826.

PMID: 36881141 DOI: 10.1007/s00068-023-02243-7.


Simultaneous bilateral quadriceps tendon rupture in a healthy young male: a case report.

Sasaki R, Nagashima M, Aibara N, Aomatsu S, Aida S, Takeshima K J Med Case Rep. 2023; 17(1):85.

PMID: 36879269 PMC: 9990254. DOI: 10.1186/s13256-023-03802-7.


Macrophages and vimentin in tissues adjacent to megaprostheses and mesh in reconstructive surgeries.

Asanuma K, Nakamura T, Iino T, Hagi T, Sudo A Commun Integr Biol. 2022; 15(1):168-181.

PMID: 36532655 PMC: 9754113. DOI: 10.1080/19420889.2022.2101193.


Spontaneous bilateral quadriceps tendon rupture treated with polyethylene terephthalate tape augmentation: Report of two consecutive cases.

Bove A, Orabona N, De Matteo V, Salati N, Di Matteo G, Citak M Jt Dis Relat Surg. 2022; 33(3):666-672.

PMID: 36345196 PMC: 9647685. DOI: 10.52312/jdrs.2022.764.