Arterial or Mixed Venous Lactate Measurement in Critically Ill Children. Is There a Difference?
Overview
Authors
Affiliations
Seven critically ill children had simultaneous measurement of whole blood lactate concentrations obtained from a systemic arterial and mixed venous (pulmonary artery) site. An excellent correlation was found (r = 0.995). The mean difference between arterial and mixed venous values was 0.02 mmol/l and the limits of agreement (+/- 0.22) were -0.20 to 0.24. The differences found were clinically insignificant (two-tailed paired Student's t-test; p = 0.36) and therefore support the continued use of arterial sampling for blood lactate measurement.
Arterial versus venous lactate: a measure of sepsis in children.
Samaraweera S, Gibbons B, Gour A, Sedgwick P Eur J Pediatr. 2017; 176(8):1055-1060.
PMID: 28600630 PMC: 5511314. DOI: 10.1007/s00431-017-2925-9.
Morris K, McShane P, Stickley J, Parslow R Intensive Care Med. 2012; 38(12):2042-6.
PMID: 23100008 DOI: 10.1007/s00134-012-2733-7.
Nascente A, Assuncao M, Guedes C, Freitas F, Mazza B, Jackiu M Sao Paulo Med J. 2011; 129(1):11-6.
PMID: 21437503 PMC: 10865908. DOI: 10.1590/s1516-31802011000100003.
Agreement between arterial and central venous values for pH, bicarbonate, base excess, and lactate.
Middleton P, Kelly A, Brown J, Robertson M Emerg Med J. 2006; 23(8):622-4.
PMID: 16858095 PMC: 2564165. DOI: 10.1136/emj.2006.035915.
Association between blood lactate and acid-base status and mortality in ventilated babies.
Deshpande S, Platt M Arch Dis Child Fetal Neonatal Ed. 1997; 76(1):F15-20.
PMID: 9059180 PMC: 1720617. DOI: 10.1136/fn.76.1.f15.