Although not widely utilized, fibreoptic techniques represent a dramatic advance in the management of the difficult intubation. Particularly suited to the awake patient in the elective setting, fibreoptic intubation can also be useful in selected emergency situations, and can be done under general anaesthesia. In the awake patient fibreoptic intubation maintains a wide margin of safety while producing minimal patient discomfort, but requires adequate local anaesthesia of the airway. Intimate familiarity with the bronchoscope and the anatomy of the upper airway is essential as is careful attention to various aspects of technique. Intubation mannequins can be readily utilized to develop dexterity in bronchoscopic manipulation and intubation workshops are also effective in improving skills. This CME article provides the clinician with a detailed approach to the technique of fibreoptic intubation based on the author's personal experience supplemented by a limited literature review. Fibreoptic intubation is not a difficult skill to master and should be in the armamentarium of all practising anaesthetists.

Citing Articles

Airway Considerations in Case of a Large Multinodular Goiter.

Kaur H, Kataria A, Muthuramalingapandian M, Kaur H Anesth Essays Res. 2017; 11(4):1097-1100.

PMID: 29284884 PMC: 5735459. DOI: 10.4103/aer.AER_86_16.


Evaluation of Fastrach Laryngeal Mask Airway as an Alternative to Fiberoptic Bronchoscope to Manage Difficult Airway: A Comparative Study.

Shyam R, Chaudhary A, Sachan P, Singh P, Singh G, Bhatia V J Clin Diagn Res. 2017; 11(1):UC09-UC12.

PMID: 28274023 PMC: 5324468. DOI: 10.7860/JCDR/2017/22001.9284.


Stridor and trismus: safe airway by oral awake emergency intubation.

van der Werf T, Ligtenberg J, van de Loosdrecht A, Tulleken J, Eindhoven G, Zijlstra J Intensive Care Med. 2001; 27(2):450-1.

PMID: 11396299 DOI: 10.1007/s001340000833.


The bamboo skewer: airway management in a patient with penetrating injury of the floor of mouth.

Ng K, Lo C Can J Anaesth. 1996; 43(11):1156-60.

PMID: 8922774 DOI: 10.1007/BF03011845.


Fibreoptic intubation in the anaesthetized patient.

Dennehy K, Dupuis J Can J Anaesth. 1996; 43(2):197-8.

PMID: 8825551 DOI: 10.1007/BF03011272.


References
1.
Gupta B, McDonald J, Brooks J, Mendenhall J . Oral fiberoptic intubation over a retrograde guidewire. Anesth Analg. 1989; 68(4):517-9. View

2.
Meschino A, Devitt J, Koch J, Szalai J, Schwartz M . The safety of awake tracheal intubation in cervical spine injury. Can J Anaesth. 1992; 39(2):114-7. DOI: 10.1007/BF03008639. View

3.
Kleeman P, Jantzen J, Bonfils P . The ultra-thin bronchoscope in management of the difficult paediatric airway. Can J Anaesth. 1987; 34(6):606-8. DOI: 10.1007/BF03010520. View

4.
Morris I . Functional anatomy of the upper airway. Emerg Med Clin North Am. 1988; 6(4):639-69. View

5.
Crosby E, Lui A . The adult cervical spine: implications for airway management. Can J Anaesth. 1990; 37(1):77-93. DOI: 10.1007/BF03007488. View