Dielectric Properties of Human Blood and Erythrocytes at Radio Frequencies (0.2-10 MHz); Dependence on Cell Volume Fraction and Medium Composition
Overview
Authors
Affiliations
The dielectric properties of human erythrocytes (red blood cells) suspended in whole blood and in isotonic media at various volume fractions (haematocrits) have been studied in the frequency range 0.2-10 MHz, in which the so-called beta-dispersion due to the Maxwell-Wagner effect is known to occur. The capacitance and conductance at 25 degrees C were measured by an instrument interfaced to a computer. The rectangular sample cavity (1 ml volume) contained four pure gold electrode pins, and the sample could be circulated by a roller pump. The frequency-dependence of the permittivity and conductivity were fitted by non-linear least squares regression. Corrections were applied for non-linearity in the dielectric increment at high haematocrit, and for electrode polarisation when diluting the blood in saline. Data were interpreted in terms of a simple equivalent resistor-capacitor circuit. From the measured haematological values the specific membrane capacitance (Cm) and the conductivities internal and external to the cells (sigma i' and sigma o' respectively) were estimated. The conductivities behaved in a predictable manner with a mean of 0.458 S.m-1 (s.d. +/- 0.044) for sigma i', whereas the value of Cm (and indeed the actual capacitance of the suspension) was dependent on the amount of plasma present. Hence, in stationary normal (anticoagulated) whole blood samples, Cm was as high as 2.98 mu F.cm-2 (s.d. +/- 0.40), in contrast to about 0.9 mu F.cm-2 in blood diluted more than two-fold (to less than 20% hct) in isotonic media. The high value remained when the diluent was plasma.(ABSTRACT TRUNCATED AT 250 WORDS)
Kakarla S, Pr U, Saravanan S, Namboodiri N J Interv Card Electrophysiol. 2024; .
PMID: 39400645 DOI: 10.1007/s10840-024-01927-3.
The inhibition of glucose uptake to erythrocytes: microwave dielectric response.
Galindo C, Latypova L, Barshtein G, Livshits L, Arbell D, Einav S Eur Biophys J. 2022; 51(4-5):353-363.
PMID: 35532810 DOI: 10.1007/s00249-022-01602-3.
Weak Vestibular Response in Persistent Developmental Stuttering.
Gattie M, Lieven E, Kluk K Front Integr Neurosci. 2021; 15:662127.
PMID: 34594189 PMC: 8477904. DOI: 10.3389/fnint.2021.662127.
John M, Rook A, Post A, Mersman A, Allen W, Schramm C Heart Rhythm O2. 2021; 1(4):290-296.
PMID: 34113883 PMC: 8183883. DOI: 10.1016/j.hroo.2020.06.006.
Berger M, Zygmanowski A, Zimmermann S Sensors (Basel). 2021; 21(7).
PMID: 33805361 PMC: 8038047. DOI: 10.3390/s21072365.