» Articles » PMID: 7865389

Endoluminal Aortic Aneurysm Repair Using a Balloon-expandable Stent-graft Device: a Progress Report

Overview
Journal Ann Vasc Surg
Publisher Elsevier
Date 1994 Nov 1
PMID 7865389
Citations 8
Authors
Affiliations
Soon will be listed here.
Abstract

We describe our experience with endoluminal repair of abdominal aortic aneurysms using the stent-graft device. Twenty-four patients underwent 25 procedures in the 27-month period ending December 31, 1992. Twenty-one of the patients were considered high-risk candidates for conventional surgical repair. The endoluminal stented grafts were aortoaortic in 16 procedures and unilateral aortoiliac in eight. One patient underwent a second procedure consisting of an ilioiliac graft to repair a separate common iliac artery aneurysm. Technical problems were primarily related to retrograde transluminal access across the iliac arteries, tortuous aneurysms, and misjudgments as to measurement of length. One patient died and another required secondary deployment of a distal stent at 4 months; subsequent aneurysm expansion mandated surgical replacement at 18 months. It is clear that this device and methodology will have to undergo further refinement before the technique is acceptable for wider clinical application. Current experience, however, is encouraging. Aneurysm exclusion with an endoluminal prosthesis is likely to become an important therapeutic alternative over the next several years.

Citing Articles

Long-Term Results of Physician-Modified Endografts for the Treatment of Elective, Symptomatic, and Ruptured Juxtarenal Abdominal Aortic Aneurysms.

Starnes B, Zettervall S, Larimore A, Singh N Ann Surg. 2024; 280(4):633-639.

PMID: 38920026 PMC: 11379358. DOI: 10.1097/SLA.0000000000006422.


Successful management of life-threatening aortoesophageal fistula: A case report and review of the literature.

Zhong X, Li G World J Clin Cases. 2022; 10(12):3814-3821.

PMID: 35647167 PMC: 9100730. DOI: 10.12998/wjcc.v10.i12.3814.


Endovascular repair of isolated post-traumatic subclavian artery false-aneurysm (FA) using gore viabahn vbx-balloon-expandable (BE) stent-graft: case report and literature review.

Perri M, Timpani C, Capoccia L, Bianchi G, Balzano R, Popolizio T Acta Biomed. 2022; 93(S1):e2022080.

PMID: 35420596 PMC: 10510997. DOI: 10.23750/abm.v93iS1.12537.


Using the Idea, Development, Exploration, Assessment, Long-Term Study Framework for Devices (IDEAL-D) to Better Understand the Evolution of Evidence Surrounding Fenestrated Abdominal Aortic Endovascular Grafts.

Zacharias N, Wang G, Sedrakyan A, Columbo J, Boyle J, Goodney P Ann Vasc Surg. 2019; 59:293-299.

PMID: 31009709 PMC: 10767621. DOI: 10.1016/j.avsg.2019.02.010.


Late conversion of endovascular to open repair of abdominal aortic aneurysms.

Forbes T, Harrington D, Harris J, DeRose G Can J Surg. 2012; 55(4):254-8.

PMID: 22617542 PMC: 3404146. DOI: 10.1503/cjs.038310.