Computer-based data acquisition systems play an important role in clinical monitoring and in the development of new monitoring tools. LabVIEW (National Instruments, Austin, TX) is a data acquisition and programming environment that allows flexible acquisition and processing of analog and digital data. The main feature that distinguishes LabVIEW from other data acquisition programs is its highly modular graphical programming language, "G," and a large library of mathematical and statistical functions. The advantage of graphical programming is that the code is flexible, reusable, and self-documenting. Subroutines can be saved in a library and reused without modification in other programs. This dramatically reduces development time and enables researchers to develop or modify their own programs. LabVIEW uses a large amount of processing power and computer memory, thus requiring a powerful computer. A large-screen monitor is desirable when developing larger applications. LabVIEW is excellently suited for testing new monitoring paradigms, analysis algorithms, or user interfaces. The typical LabVIEW user is the researcher who wants to develop a new monitoring technique, a set of new (derived) variables by integrating signals from several existing patient monitors, closed-loop control of a physiological variable, or a physiological simulator.

Citing Articles

Beagle: a near-edge X-ray absorption fine-structure spectroscopy data processing solution for beamline experiments at Pohang Accelerator Laboratory.

Park J, Lee M, Jeong S, Lee H J Synchrotron Radiat. 2023; 31(Pt 1):202-207.

PMID: 37930256 PMC: 10833428. DOI: 10.1107/S1600577523008755.


synapse: interactive support on photoemission spectroscopy measurement and analysis for non-expert users.

Masuda T, Kobayashi M, Yatani K J Synchrotron Radiat. 2023; 30(Pt 6):1127-1134.

PMID: 37885154 PMC: 10624023. DOI: 10.1107/S1600577523008305.


An Ultrasonic RF Acquisition System for Plant Stems Based on Labview Double Layer Multiple Triggering.

Huang X, Lv D, Xi R, Gao M, Wang Z, Gu L Sensors (Basel). 2023; 23(16).

PMID: 37631623 PMC: 10459184. DOI: 10.3390/s23167088.


Daiquiri: a web-based user interface framework for beamline control and data acquisition.

Fisher S, Oscarsson M, de Nolf W, Cotte M, Meyer J J Synchrotron Radiat. 2021; 28(Pt 6):1996-2002.

PMID: 34738955 PMC: 8570207. DOI: 10.1107/S1600577521009851.


Analysis and Testing of a Suitable Compatible Electrode's Material for Continuous Measurement of Glucose Concentration.

Slaninova N, Fiedorova K, Selamat A, Danisova K, Kubicek J, Tkacz E Sensors (Basel). 2020; 20(13).

PMID: 32629993 PMC: 7374362. DOI: 10.3390/s20133666.

References
1.
Beatty P . Software safety considerations in the use of closed-loop, patient-connected control systems. Br J Anaesth. 1993; 71(3):461-2. DOI: 10.1093/bja/71.3.461. View

2.
Martin J, Schneider A, QUINN M, Smith N . Improved safety and efficacy in adaptive control of arterial blood pressure through the use of a supervisor. IEEE Trans Biomed Eng. 1992; 39(4):381-8. DOI: 10.1109/10.126610. View

3.
Brannigan V . Software quality regulation under the Safe Medical Devices Act of 1990: hospitals are now the canaries in the software mine. Proc Annu Symp Comput Appl Med Care. 1991; :238-42. PMC: 2247531. View

4.
Ellis W, Jones R . Using LabVIEW to facilitate calibration and verification for respiratory impedance plethysmography. Comput Methods Programs Biomed. 1991; 36(4):169-75. DOI: 10.1016/0169-2607(91)90086-9. View

5.
Lim I, Walkup R, Vannier M . Rapid prototyping of interactive software for automated instrumentation in rehabilitative therapy. Biomed Instrum Technol. 1992; 26(3):209-14. View