» Articles » PMID: 7732071

In Vivo XRF Analysis of Mercury: the Relation Between Concentrations in the Kidney and the Urine

Overview
Journal Phys Med Biol
Publisher IOP Publishing
Date 1995 Mar 1
PMID 7732071
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

The objective of this study was to determine the concentrations of mercury in organs of occupationally exposed workers using in vivo x-ray fluorescence analysis. Twenty mercury exposed workers and twelve occupationally unexposed referents participated in the study. Their mercury levels in kidney, liver and thyroid were measured using a technique based on excitation with partly plane polarized photons. The mercury levels in blood and urine were determined using atomic absorption spectrophotometry. The detection limit for mercury in the kidney was exceeded in nine of the exposed workers, but in none of the referents. The mean kidney mercury concentration (including estimates below the detection limits) was 24 micrograms g-1 in the exposed workers, and 1 microgram g-1 in the referents. The association between mercury in the kidney and in urine was statistically significant, but it was unclear whether the relation was linear. The measurements on liver (n = 10) and thyroid (n = 8) in the exposed workers showed mercury levels below the detection limit. The study shows that it is now possible to measure the mercury concentrations in kidneys of occupationally exposed persons, using in vivo x-ray fluorescence. The estimated concentrations are in reasonable agreement with the limited human autopsy data, and the results of animal studies.

Citing Articles

Methodology using a portable X-ray fluorescence device for on-site and rapid evaluation of heavy-atom contamination in wounds: a model study for application to plutonium contamination.

Yoshii H, Yanagihara K, Imaseki H, Hamano T, Yamanishi H, Inagaki M PLoS One. 2014; 9(7):e101966.

PMID: 25010749 PMC: 4092075. DOI: 10.1371/journal.pone.0101966.


Sensing mercury for biomedical and environmental monitoring.

Selid P, Xu H, Collins E, Face-Collins M, Zhao J Sensors (Basel). 2012; 9(7):5446-59.

PMID: 22346707 PMC: 3274135. DOI: 10.3390/s90705446.


Detection of silver protein complex injections in the bovine udder using X-ray fluorescence: a preliminary investigation.

Graham S, OMeara J, Dobson H Can J Vet Res. 2005; 69(2):123-7.

PMID: 15971676 PMC: 1142179.


Cadmium, mercury, and lead in kidney cortex of the general Swedish population: a study of biopsies from living kidney donors.

Barregard L, Svalander C, Schutz A, Westberg G, Sallsten G, Blohme I Environ Health Perspect. 1999; 107(11):867-71.

PMID: 10544153 PMC: 1566723. DOI: 10.1289/ehp.107-1566723.