Image Quality Control for Digital Mammographic Systems: Initial Experience and Outlook

Overview
Journal J Digit Imaging
Publisher Springer
Date 1995 May 1
PMID 7612703
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

This report presents (1) a broad topical review and a tutorial of the possibilities for image quality control (IQC) with digital systems, and (2) results and initial experience for IQC with two commercial digital imaging systems, but with limited discussion on any particular method. Digital imaging systems used for mammographically guided digital stereotactic breast biopsy were evaluated extensively at the University of Arizona. Measurements were made of linearity, sensitivity, signal-to-noise ratio, and square-wave modulation. Images of phantoms such as the American College of Radiology Accreditation Phantom and the contrast detail mammography Phantom were evaluated as well as images of the x-ray source's focal spot. The evaluation also included the cathode ray tubes for the imaging systems. The data collected show that digital imaging systems have an important advantage over film-screen systems because they provide a digital signal as output that can be used for quantitative analysis. As a result, IQC can become a much more quantitative discipline than presently practiced, providing more information on the imaging systems under evaluation, and providing better control over their properties during actual operation.

Citing Articles

Task-based lens design with application to digital mammography.

Chen L, Barrett H J Opt Soc Am A Opt Image Sci Vis. 2005; 22(1):148-67.

PMID: 15669625 PMC: 1785332. DOI: 10.1364/josaa.22.000148.


Mammographic imaging with a small format CCD-based digital cassette: physical characteristics of a clinical system.

Vedantham S, Karellas A, Suryanarayanan S, Levis I, Sayag M, Kleehammer R Med Phys. 2000; 27(8):1832-40.

PMID: 10984230 PMC: 4280185. DOI: 10.1118/1.1286720.


Full breast digital mammography with an amorphous silicon-based flat panel detector: physical characteristics of a clinical prototype.

Vedantham S, Karellas A, Suryanarayanan S, Albagli D, Han S, Tkaczyk E Med Phys. 2000; 27(3):558-67.

PMID: 10757607 PMC: 4280189. DOI: 10.1118/1.598895.


Quality assurance and quality control of an intensive care unit picture archiving and communication system.

Tucker D, McEachern M J Digit Imaging. 1995; 8(4):162-7.

PMID: 8573625 DOI: 10.1007/BF03168715.

References
1.
Seelentag W, Panzer W . Stripping of X-ray bremsstrahlung spectra up to 300 kVp on a desk type computer. Phys Med Biol. 1979; 24(4):767-80. DOI: 10.1088/0031-9155/24/4/008. View

2.
Gray J, Anderson W, Shaw C, Shepard S, Zeremba L, Lin P . Multiformat video and laser cameras: history, design considerations, acceptance testing, and quality control. Report of AAPM Diagnostic X-Ray Imaging Committee Task Group No. 1. Med Phys. 1993; 20(2 Pt 1):427-38. DOI: 10.1118/1.597036. View

3.
CAPP M, Roehrig H, Seeley G, Fisher H, Ovitt T . The digital radiology department of the future. Radiol Clin North Am. 1985; 23(2):349-55. View

4.
Nishikawa R, Yaffe M . Signal-to-noise properties of mammographic film-screen systems. Med Phys. 1985; 12(1):32-9. DOI: 10.1118/1.595781. View

5.
Law J . The measurement and routine checking of mammography x-ray tube kV. Phys Med Biol. 1991; 36(8):1133-9. DOI: 10.1088/0031-9155/36/8/009. View