» Articles » PMID: 7561658

A Comparison of Root Canal Preparations Using Ni-Ti Hand, Ni-Ti Engine-driven, and K-Flex Endodontic Instruments

Overview
Journal J Endod
Publisher Elsevier
Specialty Dentistry
Date 1995 Mar 1
PMID 7561658
Citations 64
Authors
Affiliations
Soon will be listed here.
Abstract

This study used a modified Bramante technique and new digital subtraction software to compare root canals prepared by nickel-titanium (Ni-Ti) hand, Ni-Ti engine-driven, and stainless steel hand endodontic instruments. Sixty mesial canals of extracted human mandibular molars were randomly divided into five groups. The roots were embedded in clear resin and cross-sectioned in the apical and mid-root areas. In group A, canals were instrumented using a quarter turn/pull technique with K-Flex files. In group B, canals were prepared with Ni-Ti hand files (Mity files) using the same technique as in group A. Group C was prepared with NT Sensor engine-driven files. Group D canals were prepared with Ni-Ti Canal Master "U" hand instruments. Group E was prepared with engine-driven Ni-Ti Lightspeed instruments. Digitized images of the uninstrumented canals were compared with images of the instrumented canals. Engine-driven Ni-Ti instruments (Lightspeed and NT Sensor file) and hand instrumentation with the Canal Master "U" caused significantly less canal transportation (p < 0.05), remained more centered in the canal (p < 0.05), removed less dentin (p < 0.05), and produced rounder canal preparations than K-Flex and Mity files. Engine instrumentation with Lightspeed and NT Sensor file was significantly faster than hand instrumentation (p < 0.05).

Citing Articles

Evaluation of the effects of traditional irrigation solutions and etidronic acid on the bond strength of endodontic sealers.

Emekli G, Kaptan R, Tanalp J BMC Oral Health. 2025; 25(1):364.

PMID: 40059165 PMC: 11892174. DOI: 10.1186/s12903-025-05678-z.


Fracture Incidence of New Reciprocating Nickel-Titanium (NiTi) Files: A Cross-Sectional Retrospective Study.

Algarni Y Cureus. 2024; 16(8):e67762.

PMID: 39323712 PMC: 11422514. DOI: 10.7759/cureus.67762.


Canal-Centering and Apical Transportation Ability of Similar Cross-Section NiTi Instruments Working with Different Kinematics-Micro-CT-based Analysis.

Shareef M, Reddy S, Habeeb A, Singh T, Firdaus T, Bhattacharjee P J Pharm Bioallied Sci. 2024; 16(Suppl 2):S1365-S1368.

PMID: 38882893 PMC: 11174255. DOI: 10.4103/jpbs.jpbs_377_23.


Life span of Neoendo Flex and ProTaper Next rotary files with reciprocating motion in single-rooted teeth.

Chhabra A, Ramya K, Prathap B, Yadav P J Conserv Dent Endod. 2023; 26(4):420-423.

PMID: 37705551 PMC: 10497078. DOI: 10.4103/jcd.jcd_239_23.


Assessment of minimally invasive file systems on resistance to fracture using traditional and contracted access cavity designs in the maxillary first and second molars.

Kapadia K, Patni P, Jain P, Raghuvanshi S, Pandey S, Singhal R J Conserv Dent Endod. 2023; 26(4):395-401.

PMID: 37705550 PMC: 10497085. DOI: 10.4103/jcd.jcd_194_23.