The introduction of frequency modulated recording systems for ambulatory electrocardiographic monitoring (Oxford Medilog mark 2 and Cardiodyne cassette recorders) prompted comparison with a conventional direct recording type of recorder (Oxford Medilog mark 1). The recordings obtained by the frequency modulated recorders were very much superior to those obtained by the direct recording type of recorder. The direct recording suffered from poor low frequency response, phase shift, and cable motions artefacts. Correction of these problems with careful attention to electrode application enabled stable graphs to be obtained over 24 hours. The clinical applications were explored by comparing the results of exercie tests with a computer assisted system with frequency modulated ambulatory monitoring in 30 patients. A range of ST deviations from pure ST depressions throughout 24 hours, pure ST elevation, and a combination of ST elevation and depression were seen, suggesting a spectrum of changes hitherto unsuspected in these patients. Painless ST changes were approximately twice as common as those associated with pain. These findings indicate a valuable role for ST segment monitoring in ischaemic heart disease, particularly with the availability of high fidelity modulated tracings which do not distort ST segments.

Citing Articles

ST segment analysis by Holter Monitoring: methodological considerations.

Bjerregaard P, El-Shafei A, Kotar S, Labovitz A Ann Noninvasive Electrocardiol. 2003; 8(3):200-7.

PMID: 14510654 PMC: 6931939. DOI: 10.1046/j.1542-474x.2003.08306.x.


Projection of ST segment changes on to the front of the chest. Practical implications for exercise testing and ambulatory monitoring.

Fox K, Deanfield J, Ribero P, England D, Wright C Br Heart J. 1982; 48(6):555-9.

PMID: 7171402 PMC: 482748. DOI: 10.1136/hrt.48.6.555.


Simultaneous recording of arterial blood pressure, heart rate and ST segment in the ambulant patient: a new system.

Davies A, Cashman P, Bala Subramanian V, Raftery E Med Biol Eng Comput. 1983; 21(4):410-7.

PMID: 6888008 DOI: 10.1007/BF02442627.


Simultaneous recording of continuous arterial pressure, heart rate, and ST segment in ambulant patients with stable angina pectoris.

Davies A, Bala Subramanian V, Cashman P, Raftery E Br Heart J. 1983; 50(1):85-91.

PMID: 6860516 PMC: 481375. DOI: 10.1136/hrt.50.1.85.


Ambulatory electrocardiographic ST segment changes in healthy volunteers.

Quyyumi A, Wright C, Fox K Br Heart J. 1983; 50(5):460-4.

PMID: 6639817 PMC: 481439. DOI: 10.1136/hrt.50.5.460.


References
1.
Berson A, PIPBERGER H . The low-frequency response of electrocardiographs, a frequent source of recording errors. Am Heart J. 1966; 71(6):779-89. DOI: 10.1016/0002-8703(66)90599-0. View

2.
HINKLE Jr L, Meyer J, Stevens M, CARVER S . Tape recordings of the ECG of active men. Limitations and advantages of the Holter-Avionics instruments. Circulation. 1967; 36(5):752-65. DOI: 10.1161/01.cir.36.5.752. View

3.
Stern S, Tzivoni D . The reliability of the Holter-Avionics system in reproducing the ST-T segment. Am Heart J. 1972; 84(3):427-8. DOI: 10.1016/0002-8703(72)90382-1. View

4.
Wolf E, Tzivoni D, Stern S . Comparison of exercise tests and 24-hour ambulatory electrocardiographic monitoring in detection of ST-T changes. Br Heart J. 1974; 36(1):90-5. PMC: 1020016. DOI: 10.1136/hrt.36.1.90. View

5.
Stern S, Tzivoni D . Early detection of silent ischaemic heart disease by 24-hour electrocardiographic monitoring of active subjects. Br Heart J. 1974; 36(5):481-6. PMC: 458846. DOI: 10.1136/hrt.36.5.481. View