» Articles » PMID: 727913

[Diagnosis for the Localization of Cemented Intramedullar Stem Prostheses and ICLH-prostheses of the Hip by Means of Stereo X-ray Prints (author's Transl)]

Overview
Specialty Orthopedics
Date 1978 Aug 11
PMID 727913
Citations 2
Authors
Affiliations
Soon will be listed here.
Abstract

It is known that the loosening of artificial hip joints leads to their shift relative to the carrying bone structure. For a quantitative radiological detection of even minimal dislocations fix-points both in the carrying bone structure as well as in the prostheses have to be defined. While for the stem prostheses and cups such points can be defined directly from their geometrical structure, they have to be generated artificially for the carrying bone structure by implanted metal pins, which can easily be detected in the X-ray print. Having defined in this way a complete and appropriate set of fix-points, the position of the prosthesis relative to the bone structure is uniquely defined by the distance vectors between the different fix-points. The main biometrical steps of such a concept as well as their computational formulation and realization are derived; the main advantages and the accuracy of the technique are elucidated and critically discussed.

Citing Articles

Results of alloarthroplasty of the hip joint.

Oberthaler W, Bauer R, Sattler K Arch Orthop Trauma Surg (1978). 1980; 96(4):247-58.

PMID: 6994678 DOI: 10.1007/BF00432862.


Instability and wear of total hip prostheses determined with roentgen stereophotogrammetry.

Baldursson H, Egund N, HANSSON L, Selvik G Arch Orthop Trauma Surg (1978). 1979; 95(4):257-63.

PMID: 547966 DOI: 10.1007/BF00389695.

References
1.
Meiler J . [Limitations of detail recognition in radiographs due to threshold contrast values (author's transl)]. Rofo. 1977; 127(2):179-82. DOI: 10.1055/s-0029-1230681. View

2.
Salvati E, FREIBERGER R, WILSON Jr P . Arthrography for complications of total hip replacement. A review of thirty-one arthrograms. J Bone Joint Surg Am. 1971; 53(4):701-9. View

3.
Weigand H, Ritter G . [X-ray evaluation of the total prosthesis in hip-joint replacement and its complications]. Dtsch Med Wochenschr. 1974; 99(41):2046-50. DOI: 10.1055/s-0028-1108090. View

4.
Wagner H . [Total joint surfact replacement in the hip joint. Preliminary communication]. Arch Orthop Unfallchir. 1975; 82(2):101-6. View

5.
Suezawa Y, Dietschi C . [Secondary intervention after hip prosthesis (author's transl)]. Z Orthop Ihre Grenzgeb. 1977; 115(2):159-67. View