Quantitative Gait Analysis After Total Knee Arthroplasty for Monarticular Degenerative Arthritis

Overview
Date 1983 Jun 1
PMID 6853565
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

By quantitative gait analysis, we characterized the functional results of total knee arthroplasty in a group of twelve elderly patients with isolated degenerative arthritis of one knee. All patients had had a standard replacement arthroplasty performed at least two years before the study. In the gait analysis we used high-speed movie cameras synchronized with force platforms and electromyograms to provide kinetic and kinematic data. The data were compared with those obtained from an age-matched control group. In the patients most of the measurements of gait had been restored to normal levels. These measurements included: velocity; stride length; arcs of motion of the hip, knee, and ankle bilaterally; phasic muscle activity; and the amount of mechanical work performed. There were three patterns of external torque across the implants and in the control knee which were comparable in magnitude but varied in relative frequency between the two groups. As compared with the controls, the patients spent approximately 30 per cent more time in double-limb stance and had prolonged cycle times. These findings may have been the result of muscle weakness, neural impairment, or habit, but the cause could not be determined by this study.

Citing Articles

Portable Gait Analysis of Patients With Rotating Hinge Knee Megaprosthesis Compared With Total Knee Arthroplasty.

Gu M, Zhang J, Chen M, Wang W, Ma J, Fu X Orthop Surg. 2024; 16(12):3141-3150.

PMID: 39501823 PMC: 11608792. DOI: 10.1111/os.14270.


Comparison of gait kinetics in total and unicondylar knee replacement surgery.

Miller S, Agarwal A, Haddon W, Johnston L, Arnold G, Wang W Ann R Coll Surg Engl. 2018; 100(4):267-274.

PMID: 29484928 PMC: 5958845. DOI: 10.1308/rcsann.2017.0226.


Gait Analysis in Patients with Wide Resection and Endoprosthesis Replacement Around the Knee.

Ajit Singh V, Heng C, Yasin N Indian J Orthop. 2018; 52(1):65-72.

PMID: 29416172 PMC: 5791234. DOI: 10.4103/ortho.IJOrtho_188_17.


Drift removal for improving the accuracy of gait parameters using wearable sensor systems.

Takeda R, Lisco G, Fujisawa T, Gastaldi L, Tohyama H, Tadano S Sensors (Basel). 2014; 14(12):23230-47.

PMID: 25490587 PMC: 4299060. DOI: 10.3390/s141223230.


[Muscle biomechanics in total ankle replacement].

Valderrabano V, Hintermann B, Von Tscharner V, Gopfert B, Dick W, Nigg B Orthopade. 2006; 35(5):513-20.

PMID: 16572317 DOI: 10.1007/s00132-006-0938-6.