Cerebral Function Monitor in the Neonate. II: Birth Asphyxia

Overview
Date 1984 Apr 1
PMID 6724154
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

The cerebral function monitor (CFM) records an integrated electroencephalogram on slow-running paper, and therefore is suited to long-term, continuous monitoring. This study describes CFM patterns of 31 neonates with birth asphyxia. Three distinct types emerged: (1) a normal pattern compatible with gestational age was uniformly associated with favorable clinical outcome; (2) a completely disorganized pattern was associated with sever injury and fatal outcome; and (3) a more subtle pattern showed reversal to a more immature gestational age. The three infants with the third pattern all survived, but with varying degrees of neurological deficit. It is concluded that the CFM can be of advantage in predicting outcome for asphyxiated neonates.

Citing Articles

Risk Factors and Predictors of Outcomes in Hypoxic-Ischemic Encephalopathy in Neonates.

Shaligram R, Garud B, Malwade S, Mane S, Dua J, Bahal M Cureus. 2024; 16(11):e73407.

PMID: 39664145 PMC: 11631798. DOI: 10.7759/cureus.73407.


Amplitude-integrated electroencephalography in full-term newborns without severe hypoxic-ischemic encephalopathy: case series.

Osredkar D, Derganc M, Paro-Panjan D, Neubauer D Croat Med J. 2006; 47(2):285-91.

PMID: 16625694 PMC: 2080405.


Non-expert use of the cerebral function monitor for neonatal seizure detection.

Rennie J, Chorley G, Boylan G, Pressler R, Nguyen Y, Hooper R Arch Dis Child Fetal Neonatal Ed. 2004; 89(1):F37-40.

PMID: 14711852 PMC: 1721641. DOI: 10.1136/fn.89.1.f37.


Amplitude integrated EEG 3 and 6 hours after birth in full term neonates with hypoxic-ischaemic encephalopathy.

Toet M, Hellstrom-Westas L, Groenendaal F, Eken P, de Vries L Arch Dis Child Fetal Neonatal Ed. 1999; 81(1):F19-23.

PMID: 10375357 PMC: 1720950. DOI: 10.1136/fn.81.1.f19.