» Articles » PMID: 6712906

Rod-cone Interaction in Flicker Perimetry

Overview
Journal Br J Ophthalmol
Specialty Ophthalmology
Date 1984 May 1
PMID 6712906
Citations 11
Authors
Affiliations
Soon will be listed here.
Abstract

We have assessed the influence of the rod system on cone flicker sensitivity during flicker perimetry. For temporal frequencies above 18 Hz extrafoveal cone-mediated flicker thresholds for a white test stimulus are as much as 1.5 log units lower when measured against a large background light that saturates the rods than when measured in darkness. Following a Ganzfeld bleach extrafoveal cone flicker thresholds are at their minimum once the cones have recovered their sensitivity, but then thresholds rise as the rods begin to recover from the bleach. Our results indicate that the flicker sensitivity of the extrafoveal cone system at high temporal frequencies is influenced by the rods surrounding the flickering test stimulus. The rods reduce flicker sensitivity maximally in the dark adapted state, and their suppressive influence is minimised only by strong rod bleaches or by large backgrounds that saturate the rod system.

Citing Articles

Melanopsin photoreception differentially modulates rod-mediated and cone-mediated human temporal vision.

Uprety S, Adhikari P, Feigl B, Zele A iScience. 2022; 25(7):104529.

PMID: 35754721 PMC: 9218364. DOI: 10.1016/j.isci.2022.104529.


Rod- and cone-isolated flicker electroretinograms and their response summation characteristics.

McAnany J, Park J, Cao D Vis Neurosci. 2015; 32:E018.

PMID: 26241372 PMC: 6083831. DOI: 10.1017/S0952523815000139.


Vision under mesopic and scotopic illumination.

Zele A, Cao D Front Psychol. 2015; 5:1594.

PMID: 25657632 PMC: 4302711. DOI: 10.3389/fpsyg.2014.01594.


Lateral suppression of mesopic rod and cone flicker detection.

Cao D, Lu Y J Opt Soc Am A Opt Image Sci Vis. 2012; 29(2):A188-93.

PMID: 22330377 PMC: 3315283. DOI: 10.1364/JOSAA.29.00A188.


An extended 15 Hz ERG protocol (2): data of normal subjects and patients with achromatopsia, CSNB1, and CSNB2.

Bijveld M, Riemslag F, Kappers A, Hoeben F, van Genderen M Doc Ophthalmol. 2011; 123(3):161-72.

PMID: 21947599 DOI: 10.1007/s10633-011-9293-y.


References
1.
Wolf E, Gaeta A, Geer S . Critical flicker frequencies in flicker perimetry. Standards and confidence limits. Arch Ophthalmol. 1968; 80(3):347-51. DOI: 10.1001/archopht.1968.00980050349010. View

2.
Sokol S, RIGGS L . Electrical and psychophysical responses of the human visual system to periodic variation of luminance. Invest Ophthalmol. 1971; 10(3):171-80. View

3.
MacLeod D . Rods cancel cones in flicker. Nature. 1972; 235(5334):173-4. DOI: 10.1038/235173a0. View

4.
Kelly D . Adaptation effects on spatio-temporal sine-wave thresholds. Vision Res. 1972; 12(1):89-101. DOI: 10.1016/0042-6989(72)90139-3. View

5.
Hood D . Suppression of the frog's cone system in the dark. Vision Res. 1972; 12(5):889-907. DOI: 10.1016/0042-6989(72)90013-2. View