Percutaneous Balloon Aortic Valvuloplasty: Results in 23 Patients

Overview
Journal Am J Cardiol
Date 1984 Jan 1
PMID 6691261
Citations 53
Authors
Affiliations
Soon will be listed here.
Abstract

Percutaneous balloon aortic valvuloplasty (BAV) was performed in 23 consecutive patients with valvular aortic stenosis with no associated cardiac defects. The patients were 2 to 17 years old and were referred from 12 hospitals in 4 states. The balloon was positioned across the aortic valve and inflated to pressures of 80, 100, then 120 psi. Each inflation lasted 5 to 10 seconds. The arterial and venous catheters were connected together outside the groin to avoid excessive increase in left ventricular pressure during total aortic valve occlusion with the inflated balloon. Peak systolic aortic valve pressure gradient and cardiac output were measured before and 15 minutes after BAV. There was no significant change in cardiac output, but all patients had a lessened gradient. The gradient before BAV was 113 +/- 48 mm Hg, decreasing to 32 +/- 15 mm Hg after BAV (p less than 0.01). The left ventricular peak systolic pressure decreased from 221 +/- 54 to 149 +/- 21 mm Hg (p less than 0.01). No aortic regurgitation was noted in 13 patients and very mild aortic regurgitation was noted in 10 patients after BAV. The balloons were 10 to 20 mm in diameter, chosen at least 1 mm smaller than the diameter of the aortic valve anulus. Pressures of 100 to 120 psi were required to achieve full inflation of the balloons. Six patients had repeat cardiac catheterization studies 3 to 9 months after BAV. In none was there a significant change in peak systolic aortic valve pressure gradient or cardiac output compared with the study immediately after valvuloplasty.

Citing Articles

From an Unfolding Emergency Treatment to a Universal Shift in Therapy: The History and Evolution of the Catheter-Based Treatment of Aortic Valve Stenosis.

Agma H, Krull A, Feickert S, Ammareen R, Ince H, DAncona G Rev Cardiovasc Med. 2024; 23(10):349.

PMID: 39077143 PMC: 11267334. DOI: 10.31083/j.rcm2310349.


Current-Era Outcomes of Balloon Aortic Valvotomy in Neonates and Infants.

Christensen A, Chaturvedi R, Callahan C, Lee K, Wan A, Barron D JACC Adv. 2024; 1(1):100004.

PMID: 38939081 PMC: 11198319. DOI: 10.1016/j.jacadv.2022.100004.


Balloon Valvuloplasty in Congenital Critical Aortic Valve Stenosis in Neonates and Infants: A Rescue Procedure for the Left Ventricle.

Pfeifer J, Rentzsch A, Poryo M, Abdul-Khaliq H J Cardiovasc Dev Dis. 2024; 11(5).

PMID: 38786978 PMC: 11122585. DOI: 10.3390/jcdd11050156.


Echocardiogram-Guided Balloon Valvuloplasty of the Aortic Valve in Neonates and Infants Reduces Contrast Exposure with Maintained Efficacy and Less Aortic Regurgitation.

OHalloran C, Ramlogan S, Husain N, Fox J, Nugent A, Tannous P Pediatr Cardiol. 2023; 45(7):1485-1492.

PMID: 37391604 DOI: 10.1007/s00246-023-03188-9.


Balloon Dilatation in the Management of Congenital Obstructive Lesions of the Heart: Review of Author's Experiences and Observations-Part I.

Rao P J Cardiovasc Dev Dis. 2023; 10(6).

PMID: 37367392 PMC: 10299120. DOI: 10.3390/jcdd10060227.