» Articles » PMID: 6637575

A Roentgen Stereophotogrammetric System. Construction, Calibration and Technical Accuracy

Overview
Specialty Radiology
Date 1983 Jan 1
PMID 6637575
Citations 16
Authors
Affiliations
Soon will be listed here.
Abstract

The principles for a system of roentgen stereophotogrammetric analysis for experimental and clinical applications are presented. Only the positions of implanted reference markers in the investigated object are measured. Tantalum balls, 0.5 or 0.8 mm in diameter, are used as reference markers. Standard roentgen equipment, permitting simultaneous exposure from two roentgen tubes, is employed. The calibration equipment, a glass calibration cage containing radiopaque markers, introduces a rectangular laboratory coordinate system in the roentgen investigation. The calibration of the calibration equipment itself and the obtained methodologic accuracy in determining distances, volumes and movement parameters is described for various film/screen and marker combinations.

Citing Articles

Fully automated determination of robotic pedicle screw accuracy and precision utilizing computer vision algorithms.

Groisser B, Thakur A, Hillstrom H, Adhiyaman A, Zucker C, Du J J Robot Surg. 2024; 18(1):278.

PMID: 38960985 PMC: 11222209. DOI: 10.1007/s11701-024-02001-w.


The direct superior approach versus posterior approach for total hip arthroplasty: study protocol for a prospective double-blinded randomised control trial.

Kayani B, Konan S, Tahmassebi J, Ayuob A, Haddad F Trials. 2020; 21(1):546.

PMID: 32560737 PMC: 7304085. DOI: 10.1186/s13063-020-04484-y.


A prospective double-blinded randomised control trial comparing robotic arm-assisted functionally aligned total knee arthroplasty versus robotic arm-assisted mechanically aligned total knee arthroplasty.

Kayani B, Konan S, Tahmassebi J, Oussedik S, Moriarty P, Haddad F Trials. 2020; 21(1):194.

PMID: 32070406 PMC: 7027302. DOI: 10.1186/s13063-020-4123-8.


Prospective randomised clinical trial assessing subsidence and rotation, using radiostereometric analysis, of two modular cementless femoral stems (Global K2 and Apex).

Edmondson M, Ebert J, Nivbrant O, Wood D J Orthop. 2014; 11(2):96-102.

PMID: 25104894 PMC: 4118571. DOI: 10.1016/j.jor.2014.02.001.


Roentgen stereophotogrammetric analysis: an effective tool to predict implant survival after an all-poly unicompartmental knee arthroplasty-a 10 year follow-up study.

Bruni D, Bragonzoni L, Gagliardi M, Bontempi M, Akkawi I, Raspugli G Knee Surg Sports Traumatol Arthrosc. 2014; 23(11):3273-80.

PMID: 25026930 DOI: 10.1007/s00167-014-3106-2.