Evaluation of a Two-minute Test for Urine Screening
Overview
Affiliations
A study was conducted to evaluate the ability of a urine filtration system (Bac-T-Screen, Marion Laboratories, Inc., Kansas City, Mo.) to detect negative urine cultures within 2 min. A total of 1,000 urine specimens were tested with the Bac-T-Screen and compared with a standard semiquantitative culture plate method and the Autobac system (General Diagnostics, Warner-Lambert Co., Morris Plains, N.J.). Of the 1,000 clean voided urine specimens tested, 246 specimens had colony counts greater than or equal to 10(5) CFU/ml by the culture plate method. Of these, the Bac-T-Screen detected 65.4% (161 of 246), and the Autobac detected 63.0% (155 of 246). When pure cultures of diphtheroids, lactobacilli, and viridans streptococci other than group D and cultures containing multiple organisms were considered to be contaminants and, therefore, were excluded, there were 106 pure cultures of probable pathogens of which the Bac-T-Screen detected 76.4% (81 of 106) and the Autobac detected 90.6% (96 of 106). Some 133 specimens were uninterpretable with the Bac-T-Screen because 36 clogged the filter and 97 left a residual pigment on the filter. A majority of those clogging the filter (69.4%) had positive plate counts, whereas the majority of the pigmented urines had negative plate counts. Of those urine specimens tested. 754 were negative by the culture plate method. The false-positive rates for Bac-T-Screen and Autobac were 16.2 and 5.8%, respectively. As a urine screen, the Bac-T-Screen has a negative predictive value comparable to the Autobac system and has the advantage of being a 2-min test.
Controversies in the laboratory diagnosis of community-acquired urinary tract infection.
Morgan M, McKenzie H Eur J Clin Microbiol Infect Dis. 1993; 12(7):491-504.
PMID: 8404909 DOI: 10.1007/BF01970954.
Welch W, Thompson L, Layman M, Southern Jr P J Clin Microbiol. 1984; 20(6):1165-70.
PMID: 6394619 PMC: 271538. DOI: 10.1128/jcm.20.6.1165-1170.1984.
Reverse-flow apparatus for enhanced colorimetric detection of bacteriuria.
Wallis C, Melnick J J Clin Microbiol. 1984; 20(5):942-4.
PMID: 6392325 PMC: 271479. DOI: 10.1128/jcm.20.5.942-944.1984.
Clinical evaluation of three rapid methods for the detection of significant bacteriuria.
Bertram M, Bruckner D J Clin Microbiol. 1985; 22(1):62-7.
PMID: 4019744 PMC: 268322. DOI: 10.1128/jcm.22.1.62-67.1985.
An instrument for the immediate quantification of bacteria in potable waters.
Wallis C, Melnick J Appl Environ Microbiol. 1985; 49(5):1251-3.
PMID: 4004238 PMC: 238537. DOI: 10.1128/aem.49.5.1251-1253.1985.