» Articles » PMID: 6237722

Ascending Aortic Blood Velocity and Acceleration Using Doppler Ultrasound in the Assessment of Left Ventricular Function

Overview
Journal Cardiovasc Res
Date 1984 Oct 1
PMID 6237722
Citations 16
Authors
Affiliations
Soon will be listed here.
Abstract

We have used a 2.2 MHz continuous-wave Doppler blood velocity meter (Bach-Simpson BVM 202) to measure ascending aortic blood velocity and acceleration, and have obtained from the velocity signal a noninvasive measure of stroke volume and cardiac output by combining the Doppler technique with M-mode echocardiography. In two separate studies we have systematically altered the loading conditions of the heart with lower body pressure; and the inotropic state of the heart with dobutamine (5 micrograms . kg-1 . min-1), and documented the changes in mean velocity (MV), maximum acceleration (MA), stroke volume (SV), cardiac output (CO) and left ventricular end-diastolic dimension (EDD) (M-mode echocardiography). Application of lower body pressure to subjects in a 30 degrees head-up tilt position caused a systematic increase in preload, as shown by a 9% increase in EDD, which raised SV by a maximum of 33% (p less than or equal to 0.001) and CO by 32% (p less than or equal to 0.01), thus showing a classical Starling response; whilst there was relatively little increase in MA. Conversely, infusion of dobutamine, an inotropic agent, caused a 29.2% increase in MA (p less than or equal to 0.01) with minimal increase in SV. Thus, the ability to measure ascending aortic blood velocity allows noninvasive monitoring of changes in both inotropic state and Starling function, with considerable ease and rapidity.

Citing Articles

Laser-scanning velocimetry: a confocal microscopy method for quantitative measurement of cardiovascular performance in zebrafish embryos and larvae.

Malone M, Sciaky N, Stalheim L, Hahn K, Linney E, Johnson G BMC Biotechnol. 2007; 7:40.

PMID: 17623073 PMC: 1955438. DOI: 10.1186/1472-6750-7-40.


Haemodynamic comparison of amlodipine and atenolol in essential hypertension using the quantascope.

Tham T, Herity N, Guy S, Silke B Br J Clin Pharmacol. 1993; 36(6):555-60.

PMID: 12959272 PMC: 1364660. DOI: 10.1111/j.1365-2125.1993.tb00414.x.


Limits of corrected flow time to monitor hemodynamic status in children.

Wodey E, Carre F, Beneux X, Schaffuser A, Ecoffey C J Clin Monit Comput. 2003; 16(3):223-8.

PMID: 12578107 DOI: 10.1023/a:1009981024804.


A placebo controlled comparison of the effects of metoprolol and celiprolol on echo-Doppler measurements of cardiovascular function in normal volunteers.

Silke B, Thompson A, Leitch A, Riddell J Br J Clin Pharmacol. 1995; 40(1):37-42.

PMID: 8527266 PMC: 1365025. DOI: 10.1111/j.1365-2125.1995.tb04532.x.


Proceedings of the British Pharmacological Society. Clinical Pharmacology Section. 14-16 April 1993. Abstracts.

Br J Clin Pharmacol. 1993; 36(2):139P-182P.

PMID: 8398587 PMC: 1364582. DOI: 10.1111/j.1365-2125.1993.tb04214.x.