» Articles » PMID: 6166689

Double-decker Rocket Immunoelectrophoresis for Direct Quantitation of Complement C3 Split Products with C3d Specificities in Plasma

Overview
Publisher Elsevier
Date 1981 Jan 1
PMID 6166689
Citations 27
Authors
Affiliations
Soon will be listed here.
Abstract

A double-decker rocket immunoelectrophoresis (DD-RIE) method for direct quantitation of complement split products with C3d determinants in human plasma is described. The usefulness of the DD-RIE method for monitoring C3 activation has been assessed and compared with conventional crossed immunoelectrophoresis (CIE) for C3c determination in a patient with iatrogenic septic shock and patients with rheumatoid arthritis. In contrast with CIE the DD-RIE method is quantitative by reference to a standard curve based on an internal reference C3d preparation and its sensitivity and assay capacity are superior to CIE. All reagents and antibody preparation are commercially available and the production of standards is easy. No overlapping was observed between C3d values in plasma from healthy persons and patients with active classical rheumatoid arthritis. The DD-RIE is highly suitable for routine use in laboratories of clinical immunology.

Citing Articles

Decreased concentrations of intracellular signaling proteins in colon cancer patients with BRAF mutations.

Olsen D, Thomsen C, Andersen R, Madsen J, Jakobsen A, Brandslund I Sci Rep. 2020; 10(1):20113.

PMID: 33208845 PMC: 7675974. DOI: 10.1038/s41598-020-77109-8.


Complement Receptor 2 Based Immunoassay Measuring Activation of the Complement System at C3-Level in Plasma Samples From Mice and Humans.

Halkjaer L, Troldborg A, Pedersen H, Jensen L, Hansen A, Hansen T Front Immunol. 2020; 11:774.

PMID: 32431705 PMC: 7214740. DOI: 10.3389/fimmu.2020.00774.


NADPH oxidases and oxidase crosstalk in cardiovascular diseases: novel therapeutic targets.

Zhang Y, Murugesan P, Huang K, Cai H Nat Rev Cardiol. 2019; 17(3):170-194.

PMID: 31591535 PMC: 7880919. DOI: 10.1038/s41569-019-0260-8.


The C3dg Fragment of Complement Is Superior to Conventional C3 as a Diagnostic Biomarker in Systemic Lupus Erythematosus.

Troldborg A, Jensen L, Deleuran B, Stengaard-Pedersen K, Thiel S, Jensenius J Front Immunol. 2018; 9:581.

PMID: 29632534 PMC: 5879092. DOI: 10.3389/fimmu.2018.00581.


Monitoring of complement activation biomarkers and eculizumab in complement-mediated renal disorders.

Wehling C, Amon O, Bommer M, Hoppe B, Kentouche K, Schalk G Clin Exp Immunol. 2016; 187(2):304-315.

PMID: 27784126 PMC: 5217898. DOI: 10.1111/cei.12890.