Use of Fourier Series for the Analysis of Biological Systems

Overview
Journal Biophys J
Publisher Cell Press
Specialty Biophysics
Date 1966 May 1
PMID 5962280
Citations 27
Authors
Affiliations
Soon will be listed here.
Abstract

In an attempt to quantitate the physical behavior of biological systems, Fourier analysis has been applied to the respiratory and circulatory systems by a number of investigators. The validity of this application has been questioned on the basis that these systems are nonlinear and not strictly periodic. If these objections were valid much of the more recent work in this field would have to be re-evaluated. The applicability of Fourier analysis to these two systems was therefore investigated, both theoretically and experimentally, using on-line analysis on a LINC (laboratory instrument computer) digital computer. In normal anesthetized dogs errors introduced by deviations from periodicity and linearity were found to be within the range of measurement errors. In sinusoidally perfused aortas the amount of second harmonic produced by the vessel was less than 5%. In addition, the magnitude of errors due to faulty determination of cycle length, sampling techniques, aliasing, and A-D (analogue to digital) conversion were evaluated and found to be within the noise level of the measuring equipment when appropriate techniques were employed. Utmost care has to be used in the coupling between a transducer and the system to be measured, and dynamic calibration before each experiment is a prerequisite for successful analysis. With presently available equipment the static measurement errors can be reduced to +/-0.2 cm H(2)O for pressure transducers, 0.1 cm(3)/sec for electromagnetic flowmeters, and 5 x 10(-4) cm for measurement of radius changes. The frequency response of this equipment once properly coupled to the system is flat to at least 20 cycle/sec.

Citing Articles

Single-cell RNA-seq data augmentation using generative Fourier transformer.

Nouri N Commun Biol. 2025; 8(1):113.

PMID: 39843603 PMC: 11754799. DOI: 10.1038/s42003-025-07552-8.


A new gene tree algorithm employing DNA sequences of bovine genome using discrete Fourier transformation.

Abadeh R, Aminafshar M, Ghaderi-Zefrehei M, Chamani M PLoS One. 2023; 18(3):e0277480.

PMID: 36893167 PMC: 9997877. DOI: 10.1371/journal.pone.0277480.


Frequency-Domain Characteristics Response to Passive Exercise in Patients With Coronary Artery Disease.

Zhang X, Zhang Y Front Cardiovasc Med. 2021; 8:760320.

PMID: 34970607 PMC: 8712480. DOI: 10.3389/fcvm.2021.760320.


Toward New Modalities in VEP-Based BCI Applications Using Dynamical Stimuli: Introducing Quasi-Periodic and Chaotic VEP-Based BCI.

Shirzhiyan Z, Keihani A, Farahi M, Shamsi E, Golmohammadi M, Mahnam A Front Neurosci. 2020; 14:534619.

PMID: 33328841 PMC: 7718037. DOI: 10.3389/fnins.2020.534619.


Fourier Series Analysis for Novel Spatiotemporal Pulse Waves: Normal, Taut, and Slippery Pulse Images.

Peng B, Luo C, Sinha N, Tai C, Xie X, Xie H Evid Based Complement Alternat Med. 2019; 2019:5734018.

PMID: 31885653 PMC: 6900951. DOI: 10.1155/2019/5734018.


References
1.
Bergel D, MILNOR W . PULMONARY VASCULAR IMPEDANCE IN THE DOG. Circ Res. 1965; 16:401-15. DOI: 10.1161/01.res.16.5.401. View