» Articles » PMID: 4093608

Extended Follow-up of Patients Suspected of Having Joint Sepsis After Total Joint Replacement

Overview
Journal J Hyg (Lond)
Specialty Public Health
Date 1985 Dec 1
PMID 4093608
Authors
Affiliations
Soon will be listed here.
Abstract

During an average follow-up time of about 2 1/2 years after total hip or knee-joint replacement in 8052 patients, suspected joint infection was recorded in 85 patients whose joints had not been re-operated during that period. The hospital records of 72 of these patients were examined after a further period, averaging about 5 years. Thirty-five of these had suffered continuing major problems with the joint, 18 of which had been revised, and a further 9 joints needed such treatment. Infection was confirmed in 17 of the 35. These numbers are proportionately about three times greater than those observed among a set of matched controls followed-up for a similar period. The evidence from the extended follow-up suggests that the failure rate, unassociated with infection, reached about 5% by 7 years after operation and that late infections, manifested between about 2 1/2 and 7 years after operation, were about as frequent as those confirmed during the first 2 1/2 years.

References
1.
Salvati E, WILSON Jr P, Jolley M, Vakili F, Aglietti P, Brown G . A ten-year follow-up study of our first one hundred consecutive Charnley total hip replacements. J Bone Joint Surg Am. 1981; 63(5):753-67. View

2.
LIDWELL O, Lowbury E, Whyte W, Blowers R, Stanley S, Lowe D . Effect of ultraclean air in operating rooms on deep sepsis in the joint after total hip or knee replacement: a randomised study. Br Med J (Clin Res Ed). 1982; 285(6334):10-4. PMC: 1499116. DOI: 10.1136/bmj.285.6334.10. View

3.
LIDWELL O, Lowbury E, Whyte W, Blowers R, Stanley S, Lowe D . Infection and sepsis after operations for total hip or knee-joint replacement: influence of ultraclean air, prophylactic antibiotics and other factors. J Hyg (Lond). 1984; 93(3):505-29. PMC: 2129460. DOI: 10.1017/s0022172400065098. View

4.
LIDWELL O, Lowbury E, Whyte W, Blowers R, Stanley S, Lowe D . Bacteria isolated from deep joint sepsis after operation for total hip or knee replacement and the sources of the infections with Staphylococcus aureus. J Hosp Infect. 1983; 4(1):19-29. DOI: 10.1016/0195-6701(83)90061-0. View

5.
LIDWELL O, Lowbury E, Whyte W, Blowers R, Stanley S, Lowe D . Airborne contamination of wounds in joint replacement operations: the relationship to sepsis rates. J Hosp Infect. 1983; 4(2):111-31. DOI: 10.1016/0195-6701(83)90041-5. View