» Articles » PMID: 39943314

Wear Your Heart on Your Sleeve: Smart Textile ECG Wearables for Comfort, Integration, Signal Quality and Continuous Monitoring in Paroxysmal Atrial Fibrillation

Overview
Journal Sensors (Basel)
Publisher MDPI
Specialty Biotechnology
Date 2025 Feb 13
PMID 39943314
Authors
Affiliations
Soon will be listed here.
Abstract

Atrial fibrillation (AF), a prevalent cardiac arrhythmia and a major contributor to stroke risk, is anticipated to increase in incidence with the aging global population. For effective AF management, particularly for paroxysmal AF (PAF), long-term and accurate monitoring is essential. However, traditional monitoring methods, including Holter ECGs and implantable cardiac monitors (ICMs), present limitations in comfort, compliance and extended monitoring capabilities. Recent advancements in wearable technology have introduced smart textile-based ECG devices, which incorporate electrochemical sensors into fabrics, enabling non-invasive, continuous monitoring while enhancing user comfort. This review evaluates textile-based ECG devices by comparing their performance-assessed through AF detection rates, signal-to-noise ratio (SNR) and total analysis time-against conventional Holter monitoring and the 12-lead ECG. Furthermore, this review examines user acceptability factors, including patient-reported comfort, usability during resting and physical activities and skin-related adverse effects. The findings aim to provide insights for future device development and facilitate their integration into clinical practice.

References
1.
Machino T, Aonuma K, Komatsu Y, Yamasaki H, Igarashi M, Nogami A . Dry textile electrode for ambulatory monitoring after catheter ablation of atrial fibrillation: A pilot study of simultaneous comparison to the Holter electrocardiogram. F1000Res. 2022; 11:97. PMC: 9263574. DOI: 10.12688/f1000research.75712.2. View

2.
Singhal A, Cowie M . The Role of Wearables in Heart Failure. Curr Heart Fail Rep. 2020; 17(4):125-132. PMC: 7343723. DOI: 10.1007/s11897-020-00467-x. View

3.
Rajbhandary P, Nallathambi G, Selvaraj N, Tran T, Colliou O . ECG Signal Quality Assessments of a Small Bipolar Single-Lead Wearable Patch Sensor. Cardiovasc Eng Technol. 2022; 13(5):783-796. PMC: 8923108. DOI: 10.1007/s13239-022-00617-3. View

4.
Fabritz L, Guasch E, Antoniades C, Bardinet I, Benninger G, Betts T . Expert consensus document: Defining the major health modifiers causing atrial fibrillation: a roadmap to underpin personalized prevention and treatment. Nat Rev Cardiol. 2015; 13(4):230-7. DOI: 10.1038/nrcardio.2015.194. View

5.
Steinberg C, Philippon F, Sanchez M, Fortier-Poisson P, OHara G, Molin F . A Novel Wearable Device for Continuous Ambulatory ECG Recording: Proof of Concept and Assessment of Signal Quality. Biosensors (Basel). 2019; 9(1). PMC: 6468449. DOI: 10.3390/bios9010017. View