Clinical Evaluation of a Rapid Reciprocal-Flow PCR Assay and Real-Time PCR Assay with Quenching Probe for Detection of Complex

Abstract

This study investigated the diagnostic efficiencies of two assays for the detection of complex: (1) the reciprocal-flow real-time polymerase chain reaction (PCR)-based GeneSoC assay and (2) the real-time PCR based GENECUBE MTB assay with quenching probe. These assays were performed for stored clinical samples and results were compared with the confirmed results based on culture and COBAS TaqMan MTB assay. A total of 53 samples (20 confirmed positives and 33 confirmed negatives) were included in the performance analysis. The GeneSoC assay showed concordance in all 53 samples, regardless of specimen type, while the GENECUBE MTB assay showed concordance in 19 of the 20 confirmed positive samples and all 33 confirmed negative samples. The overall agreement was 100.0% for the GeneSoC assay and 98.1% for the GENECUBE MTB assay. Positive and negative percent agreements were 100.0% each for the GeneSoC assay and 95.0% and 100.0%, respectively, for the GENECUBE MTB assay. Both the GeneSoC and GENECUBE MTB assays exhibited excellent performance in detecting complex. The GeneSoC assay is useful for independent assays of individual samples, whereas the GENECUBE MTB assay is suitable for batch assays of multiple samples.

References
1.
Hara T, Suzuki H, Oyanagi T, Koyanagi N, Ushiki A, Kawabata N . Clinical evaluation of a non-purified direct molecular assay for the detection of Clostridioides difficile toxin genes in stool specimens. PLoS One. 2020; 15(6):e0234119. PMC: 7269250. DOI: 10.1371/journal.pone.0234119. View

2.
Ito Y, Iwashima S, Hayano S, Nishio T, Shiozawa R, Yata S . Rapid Detection of the Macrolide Sensitivity of Pneumonia-Causing Mycoplasma pneumoniae Using Quenching Probe Polymerase Chain Reaction (GENECUBE). Mol Diagn Ther. 2018; 22(6):737-747. DOI: 10.1007/s40291-018-0360-x. View

3.
Hida Y, Uemura K, Sugimoto H, Kawashima Y, Koyanagi N, Notake S . Evaluation of performance of the GENECUBE assay for rapid molecular identification of Staphylococcus aureus and methicillin resistance in positive blood culture medium. PLoS One. 2019; 14(7):e0219819. PMC: 6634395. DOI: 10.1371/journal.pone.0219819. View

4.
Park K, Kim J, Lee J, Hwang Y, Jeon K, Koh W . Comparison of the Xpert MTB/RIF and Cobas TaqMan MTB assays for detection of Mycobacterium tuberculosis in respiratory specimens. J Clin Microbiol. 2013; 51(10):3225-7. PMC: 3811628. DOI: 10.1128/JCM.01335-13. View

5.
Yoshida S, Tsuyuguchi K, Kobayashi T, Shimatani Y, Inoue Y . Effect of sputum quality on Mycobacterium avium-intracellulare complex lung disease diagnosis and treatment initiation according to disease type. Diagn Microbiol Infect Dis. 2022; 104(3):115773. DOI: 10.1016/j.diagmicrobio.2022.115773. View