Liver Elastography for Liver Fibrosis Stratification: A Comparison of Three Techniques in a Biopsy-Controlled MASLD Cohort

Abstract

The aim of this study was to investigate the accuracy in fibrosis staging of a novel shear wave elastography (SWE) device (S-Shearwave Imaging by Samsung) and a previously validated 2D-SWE by Supersonic Imagine (SSI) in patients with biopsy proven metabolic dysfunction-associated steatotic liver disease (MASLD). This prospective study included 75 consecutive patients with MASLD who underwent liver biopsy for suspected MASH. All patients underwent S-Shearwave Imaging by Samsung and 2D-SWE with SSI on the same day of liver biopsy. Fibrosis was histologically assessed using the METAVIR classification system. Agreement between the equipment was assessed with the Pearson coefficient. A receiver operator characteristic curve (ROC) analysis with the Youden index was used to establish thresholds for fibrosis staging. A good correlation was found between S-Shearwave Imaging by Samsung and 2D-SWE with SSI (Pearson's R = 0.68; < 0.01). At multivariate regression analysis, S-Shearwave Imaging was associated with advanced fibrosis (≥F3) independently from age, diabetes and platelets (OR 2.94, CI 1.69-5.11, < 0.01). The fibrosis diagnostic accuracy of both S-Shearwave Imaging and 2D-SWE was good to optimal with AUROCs of 0.81 and 0.70 for significant fibrosis (≥F2), 0.94 and 0.91 for severe fibrosis (≥F3), respectively. The accuracy of S-Shearwave is not significantly different from Fibroscan and Agile3+ (DeLong test value 0.16 and 0.15, respectively) while is slightly better than 2D-SWE, FIB4 and NFS (DeLong test value < 0.05). For S-Shearwave Imaging by Samsung, the best cut-off values for diagnosing fibrosis ≥F2, ≥F3 were, respectively, 7.9 kPa (Sens 74.4%, Spec 87.5%) and 8.1 kPa (Sens 95.6%, Spec 78.8%). For 2D-SWE by SSI, the best cut-off values for diagnosing fibrosis ≥F2, ≥F3 were, respectively, 7.2 kPa (Sens 55.8%, Spec 84.4%) and 7.6 kPa (Sens 82.6%, Spec 84.6%). S-Shearwave Imaging is a useful and reliable non-invasive technique for staging liver fibrosis in patients with MASLD. Its diagnostic accuracy is non-inferior to other shear wave elastography techniques (TE and 2D-SWE by SSI).

References
1.
Rinella M, Lazarus J, Ratziu V, Francque S, Sanyal A, Kanwal F . A multisociety Delphi consensus statement on new fatty liver disease nomenclature. J Hepatol. 2023; 79(6):1542-1556. DOI: 10.1016/j.jhep.2023.06.003. View

2.
Papastergiou V, Tsochatzis E, Burroughs A . Non-invasive assessment of liver fibrosis. Ann Gastroenterol. 2014; 25(3):218-231. PMC: 3959378. View

3.
Dietrich C, Bamber J, Berzigotti A, Bota S, Cantisani V, Castera L . EFSUMB Guidelines and Recommendations on the Clinical Use of Liver Ultrasound Elastography, Update 2017 (Long Version). Ultraschall Med. 2017; 38(4):e16-e47. DOI: 10.1055/s-0043-103952. View

4.
Kleiner D, Brunt E, Van Natta M, Behling C, Contos M, Cummings O . Design and validation of a histological scoring system for nonalcoholic fatty liver disease. Hepatology. 2005; 41(6):1313-21. DOI: 10.1002/hep.20701. View

5.
Friedman S, Pinzani M . Hepatic fibrosis 2022: Unmet needs and a blueprint for the future. Hepatology. 2021; 75(2):473-488. DOI: 10.1002/hep.32285. View