Characterization of Ultraviolet-Degraded Polyethylene Terephthalate Film Using a Complementary Approach: Reactive Pyrolysis-Gas Chromatography-Mass Spectrometry and Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry

Overview
Date 2025 Jan 22
PMID 39839743
Authors
Affiliations
Soon will be listed here.
Abstract

Polyethylene terephthalate (PET) is widely used across various industries owing to its versatility and favorable properties, including application in beverage bottles, food containers, textile fibers, engineering resins, films, and sheets. However, polymer materials are susceptible to degradation from factors such as light, oxygen, and heat. Therefore, it is crucial to understand the structural changes that occur during degradation and the extent of these changes. This report investigates the structural alterations in PET films resulting from ultraviolet (UV) irradiation utilizing pyrolysis-gas chromatography time-of-flight mass spectrometry (Py-GC-TOFMS) and matrix-assisted laser desorption/ionization-time-of-flight mass spectrometry (MALDI-TOFMS). Using the reactive Py-GC-TOFMS, we estimated the composition of the pyrolysis products resulting from UV degradation through electron ionization, soft ionization, and exact mass measurements. Additionally, artificial intelligence (AI)-based structure analysis was performed to evaluate these compounds' structures. Notably, most degradation products were not found in the National Institute of Standards and Technology database, underscoring the effectiveness of our approach. Using MALDI-TOFMS analysis, we determine the changes in the end groups before and after UV irradiation. This analysis confirmed the generation of a series of carboxylic acid end groups as a result of degradation, a polymer series not detected by reactive pyrolysis GC-MS. We also explored degradation in the depth direction, demonstrating that degradation progresses gradually to depths of several micrometers. Our findings highlight the importance of employing mass spectrometry techniques for a comprehensive analysis of polymer degradation.

References
1.
Cody R, Fukudome T, Ubukata M . Integrated data analysis making use of the total information from gas chromatography and high-resolution time-of-flight mass spectrometry to identify qualitative differences between two whisky samples. Rapid Commun Mass Spectrom. 2021; 36(3):e9225. DOI: 10.1002/rcm.9225. View

2.
Ohtani H, Iura T . Complementary Characterization of End Groups in Radically Polymerized Poly(methyl methacrylate) by Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry and Pyrolysis-Gas Chromatography-Mass Spectrometry. Mass Spectrom (Tokyo). 2016; 3(Spec Iss 3):S0041. PMC: 4321344. DOI: 10.5702/massspectrometry.S0041. View

3.
Satoh T, Sato T, Tamura J . Development of a high-performance MALDI-TOF mass spectrometer utilizing a spiral ion trajectory. J Am Soc Mass Spectrom. 2007; 18(7):1318-23. DOI: 10.1016/j.jasms.2007.04.010. View

4.
Wallace W, Moorthy A . NIST Mass Spectrometry Data Center standard reference libraries and software tools: Application to seized drug analysis. J Forensic Sci. 2023; 68(5):1484-1493. PMC: 10517720. DOI: 10.1111/1556-4029.15284. View

5.
Stein S . Estimating probabilities of correct identification from results of mass spectral library searches. J Am Soc Mass Spectrom. 2013; 5(4):316-23. DOI: 10.1016/1044-0305(94)85022-4. View